Operations and Maintenance Manual

Table Of Contents
VS300 Operations and Maintenance Manual Operating the transmitter
Issue 10.0 2019-01-18 Page 2-173
Figure 2.147: Remote Inputs Screens (Input 1 shown)
Use the up and down buttons to select the desired remote input (1 through 10) from the list.
Each screen shows the current remote input parameter (e.g.,
RF On/Off
), as well as the polarity
(e.g.,
Falling edge RF On
) and current state (e.g., high, low) of the corresponding input pin. Use
the right-arrow button to enter the
Selection/Polarity
screen for the selected input to allow
editing of the selection or the polarity. Press cancel (
X
) to return to the previous menu.
If you save a change to a remote input via the front panel UI, it will also be displayed on the
AUI page.
Remote Outputs - Front Panel
Using the
Remote Outputs
screens (see Figure 2.148), you can configure up to 16 remote
outputs that indicate either the presence of various alarms or the status of operator controlled
circuits.
Nautel sets remote output defaults prior to shipping. See the VS300 Pre-installation Manual for
details.
Note:
The selection and polarity options for remote inputs are the same as described in
Select Input Channel - AUI on page 2-163 and Configure Input control logic -
AUI on page 2-164.