Operations and Maintenance Manual
Table Of Contents
- Release control record
- Section 1: Description
- Section 2: Operating the transmitter
- User Interfaces
- Viewing Transmitter Log
- Viewing AUI Tool Menu Panels
- Viewing Real-Time Meters
- Managing Presets
- Enabling Remote Control
- Resetting Alarms
- Viewing Transmitter Status
- System Settings
- System Settings - Front Panel UI
- Setting User Accounts
- User Settings - AUI
- User Settings - Front Panel UI
- Configuring Remote Inputs and Outputs
- Scheduler
- Audio Player
- Enabling and Operating the Orban Audio Processor
- Figure 2-1 : VS Transmitter Front Panel Display Menu Tree (Sheet 1 of 2)
- Figure 2-2 : VS Transmitter Front Panel Display Menu Tree - Edit Presets (Sheet 2 of 2)
- Figure 2-3 : VS Transmitter AUI Flow Diagram
- Section 3: Routine maintenance
- Section 4: Non-standard maintenance
- Section 5: List of terms
VS300 Operations and Maintenance Manual Non-standard maintenance
Page 4-8 Issue 10.0 2019-01-18
Configuring the primary audio preset
1. Go to
Menu
/
Presets
/
Load
. The
Load Preset
window in Figure 4.1 shall display.
2. Select your primary or normal preset to allow editing of its audio loss parameters.
Click
Load
.
3. The setup page for the selected preset should appear. Click the
Other Settings
tab (see
Figure 4.4 on page 4-8).
4. Open the
Mod Loss Timeout
field’s drop-down menu. Select
Enabled
. This will display
five sub-fields -
Action
,
Mod Loss Preset
,
Timeout Minutes
,
Timeout Seconds
and
Threshold
.
–Open the
Action
field’s drop-down menu. Select
Change Preset
.
–Open the
Mod Loss Preset
field’s drop-down menu. Select the newly created
backup audio preset.
– Enter in the
Timeout Minutes
and/or
Timeout Seconds
fields the desired delay
between the loss of audio and the action to change to the backup preset.
– Enter in the
Threshold
field the desired percentage level of audio at which the
timeout period begins. Typically, this is set to 10%.
Figure 4.4: Normal Preset - Other Audio screen