Operations and Maintenance Manual

Table Of Contents
VS300 Operations and Maintenance Manual Operating the transmitter
Issue 10.0 2019-01-18 Page 2-17
The top banner is permanent on all AUI pages and includes:
Nautel Logo
: From any page, click the Nautel logo to log out and return to the login window.
Date & Time
: Displays day, month, year and current time. From any AUI page, click the date
or time to go to the
Time Setup
page (see Setting the Clock on page 2-144).
Active Preset:
Displays the name of the active preset, power set point based on the active
preset, current forward power and reflected power levels, as well as the operating mode and
carrier frequency (see Activating presets using the AUI on page 2-55).
Active Exciter
: Displays the active exciter (internal or external) and the FM modulation, with
rms (yellow) and peak (red) values.
The bottom banner is also permanent on all AUI pages and includes:
RF On
: Click to enable the transmitter’s RF power stage.
RF Off
: Click to disable the transmitter’s RF power stage.
Activity Window
: Displays various messages to reflect specific user interface commands, such as
RF on/off, local/remote control, or reset.
Menu
: Click to display the
Menu
page, which allows navigation to various other pages (see
AUI Menu page on page 2-21).
Status
: Click to display the
Transmitter Status
page (see Viewing Transmitter Status on page 2-
97), which provides current alarm and status details for the transmitter. When the
Status
button is red, one or more alarms of severity level 10 is being reported; the transmitter is in an
‘off-air’ state. When the
Status
button is orange, one or more alarms of severity level 5 (but
none of severity level 10) is being reported, but the transmitter is still ‘on-air’, possibly at
reduced power. When the
Status
button is green, the transmitter is operating normally. In this
case, there are no alarms being reported, or there is one or more alarms of severity level 1 (but
none of severity level 5 or 10). This page is also available through the Menu page.
Log
: Click to shortcut to the
Transmitter Log
page, which displays historical alarm and status
records for the transmitter (see Viewing Transmitter Log on page 2-23).
Local/Remote
: Displays the operational control status of the transmitter. If
Local
is highlighted
green, only local control of the transmitter is possible. If both
Local
and
Remote
are
highlighted green, both local and remote controls are enabled. To change the local/remote
status from the front panel display, see Enabling Remote Control on page 2-96.