VX150 TO VX2 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS
VERSION 0.1 2020-12-01 PAGE 3.1.7
NOTE
: Table 3.1.1 on page 3.1.9
contains a column for most alarms that can occur, sorted
alphanumerically for each sub-system, including both the names displayed on the remote AUI and, if
different, the front panel display. The
Description and Troubleshooting Action
column provides a brief
description of the alarm, troubleshooting tips and a cross-reference to more detailed troubleshooting,
as applicable
.
4. If troubleshooting and subsequent replacement of a suspect PWB or module causes the alarm to
disappear from the Alarms page, the alarm has been successfully cleared. If the fault condition
does not clear, contact Nautel.
NOTE: Before undertaking any troubleshooting, record all remote AUI meter readings and note if any
other alarms are displayed on the Alarms page. Record all alarms. The most convenient way to do this
is by using the remote AUI’s Menu -> Reports page to download a report of the Alarm History (see
“Alarm History” in the Operations & Maintenance Manual). Another method is to use a web browser
over a LAN connection to save screen shots of critical status, meter and alarm pages. Go to the
Dashboard -> Meters page to view (and save) detailed information (see “Viewing Meters” in the
Operations & Maintenance Manual).