Troubleshooting Manual
Table Of Contents
- Contact Information
- RELEASE CONTROL RECORD
- SECTION 3.1: Responding to alarms
- SECTION 3.2: Parts Information
- SECTION 3.3: Reading Electrical Schematics
- Figure SD-14: NAPF16 Low Pass Filter PWB
- Figure SD-15: NAPP15 Directional Coupler Bottom PWB
- Figure SD-1: VX150/VX300/VX600 and VX1 Transmitter - Control/Monitor Stage
- Figure SD-2: VX150/VX300/VX600 and VX1 Transmitter - Ac and RF Power Stages
- Figure SD-3: VX1.5/VX2 Transmitter - Control/Monitor Stage
- Figure SD-4: VX1.5 Transmitter - Ac and RF Power Stages
- Figure SD-5: NAPI189 Analog Audio PWB (Sheet 1 of 2)
- Figure SD-7: NAPI187 System Interface PWB (Sheet 1 of 2)
- Figure SD-8: NAPI187 System Interface PWB (Sheet 2 of 2)
- Figure SD-9: NAPI188/01 Power Supply Interface PWB, 2 kW (VX150/VX300/VX600)
- Figure SD-10: NAPI188 Power Supply Interface PWB, 3.5 kW (VX1/VX1.5/VX2)
- Figure SD-11: NAPI193 Front Panel User Interface PWB
- Figure SD-12: NAPA41 Pre-Amp/IPA PWB
- Figure SD-13: NAPA40 Power Amplifier PWB
- Figure SD-16: NAPH15 2-Way Splitter PWB (VX1.5/VX2)
- Figure SD-6: NAPI189 Analog Audio PWB (Sheet 2 of 2)
- SECTION 3.4: Mechanical Drawings
- Figure MD-1: VX150/VX300/VX600/VX1 Transmitters
- Figure MD-4: NAPI187 System Interface PWB
- Figure MD-5: NAPI188/01 Power Supply Interface PWB (VX150/VX300/VX600)
- Figure MD-11: NAPP15 Directional Coupler PWB
- Figure MD-12: NAPH15 2-Way Splitter PWB (VX1.5/VX2)
- Figure MD-7: NAPI193 Front Panel User Interface PWB
- Figure MD-6: NAPI188 Power Supply Interface PWB (VX1/VX1.5/VX2)
- Figure MD-13: 2-Way Combiner PWB (Nautel Part # PU03A) (VX1.5/VX2)
- Figure MD-8: NAPA41 Pre-Amp/IPA PWB
- Figure MD-9: NAPA40 Power Amplifier PWB
- Figure MD-10: NAPF16 Low Pass Filter PWB
- Figure MD-2: VX1.5/VX2 Transmitter
- Figure MD-3: NAPI189 Analog Audio PWB
- SECTION 3.5: List of terms
- Blank Page
VX150 TO VX2 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS
VERSION 0.1 2020-12-01 PAGE 3.1.7
NOTE
: Table 3.1.1 on page 3.1.9
contains a column for most alarms that can occur, sorted
alphanumerically for each sub-system, including both the names displayed on the remote AUI and, if
different, the front panel display. The
Description and Troubleshooting Action
column provides a brief
description of the alarm, troubleshooting tips and a cross-reference to more detailed troubleshooting,
as applicable
.
4. If troubleshooting and subsequent replacement of a suspect PWB or module causes the alarm to
disappear from the Alarms page, the alarm has been successfully cleared. If the fault condition
does not clear, contact Nautel.
NOTE: Before undertaking any troubleshooting, record all remote AUI meter readings and note if any
other alarms are displayed on the Alarms page. Record all alarms. The most convenient way to do this
is by using the remote AUI’s Menu -> Reports page to download a report of the Alarm History (see
“Alarm History” in the Operations & Maintenance Manual). Another method is to use a web browser
over a LAN connection to save screen shots of critical status, meter and alarm pages. Go to the
Dashboard -> Meters page to view (and save) detailed information (see “Viewing Meters” in the
Operations & Maintenance Manual).