Operation Manual
36
Problem Check Solution
Nodisplay/partialdiplay/unit
will not turn on
Checkelectrical(wall)outlet Makesureunitispluggedintoafunctioningwall
outlet.
Checkconnectionatfront(recumbent)
orrear(upright)ofunit
Connection should be secure and undamaged.
Replace adapter or connection at unit if either
are damaged.
Checkdatacableintegrity Allwiresincableshouldbeintact.Ifanyare
visibly crimped or cut, replace cable.
Checkdatacableconnections/
orientation
Be sure cable is connected securely and
orientedproperly.Smalllatchonconnector
should line up and snap into place.
Checkconsoledisplayfordamage Checkforvisualsignthatconsoledisplay
iscrackedorotherwisedamaged.Replace
Console if damaged.
ConsoleDisplay IfConsoleonlyhaspartialdisplayandall
connections are fine, replace the Console.
Iftheabovestepsdonotresolvetheproblem,
contact Customer Care for further assistance.
UnitoperatesbutContactHR
not displayed
HR cable connection at Console Makesurecableisconnectedsecurelyto
Console.
HRcableboxconnection Makesurecablesfromhandlebarsandcable
toConsolearesecureandundamaged.Some
modelsmayrequiretheseatbackberaisedto
accesscablebox.
Sensorgrip MakesurehandsarecenteredonHRsensors.
Handsmustbekeptstillwithrelativelyequal
pressure applied to each side.
Dryorcallousedhands Sensorsmayhavedifficultywithdriedoutor
calloused hands. A conductive electrode cream
suchas“SignaCrème”or“Buh-Bump”canhelp
makebetterconduct.Theseareavailableonthe
web or at medical or some larger fitness stores.
Handlebars Iftestsrevealnootherissues,Handlebars
should be replaced.
UnitoperatesbutTelemetric
HR not displayed
ChestStrap Strapshouldbe“Polar”compatible.Makesure
strapisdirectlyagainstskinandcontactareais
moist.
Interference Try moving unit away from sources of
interference(TV,Microwave,etc).Ifinterference
is eliminated and HR still does not function,
replace strap and Console.
Consoledisplays“E2”error
code
Checkdatacableintegrity Allwiresincableshouldbeintact.Ifanyarecut
or crimped, replace cable.
Checkdatacableconnections/
orientation
Makesurecableisconnectedsecurelyand
orientedproperly.Smalllatchonconnector
should line up and snap into place.
Console Electronics Iftestsrevealnootherissues,Consoleshould
be replaced.
TROUBLESHOOTINg