Treadmill User Manual
NAUTILUS
®
HEART RATE MONITORING
7
Maintaining the Transmitter Belt
Clean the chest belt regularly with mild soap and water, then dry thoroughly — 
residual sweat and moisture keeps the transmitter active and will drain the battery 
in the transmitter. Do not use abrasives or chemicals such as steel wool or alcohol 
for cleaning, as they can damage the electrodes permanently. The supplied chest 
belts use a sealed battery and are non-replaceable. Batteries in a chest belt will last 
on average for 1500-2000 hours of use. Replacement belts can be purchased from 
an Authorized Nautilus
®
 Fitness Retailer.
Contact Heart Rate (T7.18 model only)
Through the use of stainless steel sensors built into the handle bar and using 
sophisticated software, heart rate can be checked at any time during a workout. As 
with the wireless telemetry chest belt, the heart rate is shown on the display in the 
same manor. 
The contact heart rate system’s ability to detect a heart rate signal is infl uenced by 
several factors. Movement of the muscles of the upper body produces an electrical 
signal that will interfere with the detection of the 
heart rate signal by the sensors. Movement of the 
hands while they are in contact with the sensors 
also produces interference. For this reason users 
should avoid moving their hands while using the 
contact heart rate grips. For reasons of safety it is 
also recommended that users not use the contact 
heart rate feature while running and instead use 
the telemetry chest belt method. Calluses and 
hand lotion act as an insulating layer to reduce the 
signal strength. Also, the EKG signal generated 
by some individuals is not strong enough to be detected by the sensors. These 
individuals should opt for the telemetry method of heart rate monitoring.  
Contact heart rate input signals are acquired only during contact between your 
hands and the stainless steel sensors on the handrails. To use the contact heart rate 
feature, place your hands around the handles so that your hands touch both the top 
and the bottom of the sensors. After the initial contact heart rate signal is detected, 
the controller will enter a validation phase requiring a good heart beat signal within 
10 to 15 seconds, or until the system acquires a valid signal. During the validation 
phase the display will not recognize telemetry heart rate signals. If, during exercise, 
the heart rate displayed is erratic, it may be helpful to remove your hands from the 
handles, wipe them and place them back on the handles. 
HEART RATE MONITORING
T7_16-18_OM.indd 7 11/12/04 3:30:14 PM










