Safety Data Sheet
Extinguishing Media
Specific Hazards
arising from the
chemical
Product is or contains a sensitizer. May cause sensitization by skin contact.
Hazardous
Combustion
Products
Carbon oxides.
Explosion Data
Sensitivity to Mechanical Impact: No.
Sensitivity to Static Discharge: No.
Protective
Equipment
and precautions for
firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand,
MSHA/NIOSH (approved or equivalent) and full protective gear.
Section 6. Accidental Release Measures
Personal Precautions,
protective equipment,
and emergency
procedures
Personal Precautions: Avoid contact with skin, eyes or clothing. Ensure adequate
ventilation. Use personal protective equipment as required. Evacuate personnel to
safe areas.
Other Information: Refer to protective measures listed in Sections 7 and 8.
Environmental
Precautions
Refer to protective measures listed in Sections 7 and 8. Prevent further leakage or
spillage if safe to do so.
Methods and material
for containment and
cleaning up
Methods for Containment: Prevent further leakage or spillage if safe to do so.
Methods for cleaning up: Pick up and transfer to properly labeled containers.
Section 7 – Handling and Storage
Precautions for safe
handling
Handling: In case of rupture. Use personal protection equipment. Avoid contact
with skin, eyes or clothing. Ensure adequate ventilation. Do not breathe
dust/fume/gas/mist/vapors/spray.
Conditions for safe
storage, including any
Storage: Keep containers tightly closed in a dry, cool and well-ventilated place.
incompatibilities
Incompatible Products: Strong acids. Strong oxidizing agents. Strong bases.
Section 8. Exposure Controls/Personal Protection
Control parameters
Exposure Guidelines
Exposure
Guidelines
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt
Oxide
(CoLiO2)
12190-79-3
TWA: 0.02 mg/m³
---
---
Copper
7440-50-8
TWA:0.2mg/m³
fume
TWA:1mg/m³ Cu
dust and mist
TWA:0.1mg/m³ fume
TWA:1mg/m³ dust and mist
(vacated) TWA:0.1g/m³ Cu
dust,fume,mist
IDLH:100mg/m
3
dust,fume
and mist
TWA:1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume