Operation Manual

Table Of Contents
Section 6 - AIS setup menu (AIS SETUP)
Hold down CALL/MENU key for about 1 second to access the following AIS SETUP options.
The following menu options are explained in this section.
AIS SETUP AIS FUNC Section 6-1
AIS DISPLAY Section 6-2
BAUD RATE Section 6-3
GPS REDIR Section 6-4
CPA ALARM Section 6-5
CPA Section 6-6
TCPA Section 6-7
5-9 DSC Test Reply (TEST REPLY)
You can respond to incoming DSC TEST calls with an automatic response or with a manual
response.
• MANUAL manual response is required, press ENT to confirm or press EXIT to cancel.
• AUTO automatically replies after a 10 second delay with an ACK to any incoming
DSC TEST call.
DSC SETUP
LL REPLY
AUTO SWITC
TEST REPLY
TIMEOUT
TEST REPLY
AUTO
MANUAL
5-10 Set the inactivity timer (TIMEOUT)
You can set the inactivity timer with the following options:
• AUTOMATED you can set the inactivity timer to automatically timeout after a
period of inactivity for the following two categories: NON-DISTRESS or
DISTRESS.
Timeout options are:
DISTRESS: NO TIMEOUT; 5 MINS; 10 MINS (default is NO TIMEOUT)
NON-DISTR: NO TIMEOUT; 10 MINS; 15 MINS (default is 15 MINS)
• NON AUTO you can set the inactivity timer to exit any non-automated procedure
activity.
Timeout options are:
NO TIMEOUT; 10 MINS; 15 MINS (default is 10 MINS)
Note: If NO TIMEOUT is selected, then you must press the EXIT key to exit the procedure.
Example: to set a 10 minute TIMEOUT for non-automated functions:
1. Select TIMEOUT, then select NON AUTO
2. Select desired timeout period: NO TIMEOUT, 10 MINS or 15 MINS
NON AUTO
NO TIMEOUT
10 MINS
15 MINS
TIMEOUT
AUTOMATED
NON AUTO
DSC SETUP
LL REPLY
AUTO SWITC
TEST REPLY
TIMEOUT
In this example, 10 MINS has been selected, meaning the radio will exit any non-automated
procedure after a period of 10 minutes of non-activity.
Simrad - RS35 Operation InstructionsSimrad - RS35 Operation Instructions 4342
See sections 1-3 and 1-4 if you want to know how to move around the menu and enter, save
and change data.
6-1 Enable AIS functionality (AIS FUNC)
The AIS function can be turned ON or OFF. When AIS functionality is selected, the AIS symbol
AIS
is shown on the LCD.
AIS SETUP
AIS FUNC
AIS DISPLAY
BAUD RATE
GPS REDIR
AIS FUNC
ON
OFF
6-2 AIS data display format (AIS DISPLAY)
When viewing the AIS plotter screen, AIS targets can be displayed with the vessels name or
the vessels MMSI.
AIS SETUP
AIS DISPLAY
BAUD RATE
GPS REDIR
CPA ALARM
AIS DISPLAY
SHIP MMSI
SHIP NAME
6-3 AIS baud rate (BAUD RATE)
AIS data can be output to a compatible chart-plotter / MFD or PC via the NMEA port. The
NMEA port baud rate can be set to 4800 or 38400. The default setting is 38400. If 4800 is
selected, a warning that data may be lost is displayed.
AIS SETUP
BAUD RATE
GPS REDIR
CPA ALARM
CPA
AIS SETUP
38400
4800
AIS INFO
MAY BE LOST!
NO
YES