Chapter 2: Installing the Hardware Infrastructure 2-15
Cable Use
Manufacturer Manufacturer
Part Number
Description
Power Belden 6100UE 2 conductor, 14 AWG (2 mm
2
) stranded,
unshielded, plenum rated
Power Belden 5100UE 2 conductor, 14 AWG (2 mm
2
) stranded,
unshielded, non-plenum rated
Data Belden 1585A 4 pair, CAT5, 24 AWG (0.2 mm
2
) solid,
unshielded, plenum rated
Data Belden 1583A 4 pair, CAT5, 24 AWG (0.2 mm
2
)
`11`solid, unshielded, non-plenum rated
Note: When installing into a plenum type ceiling, plenum rated wire
may be required by local or national electrical codes. Some suspended
ceilings are considered plenums; open ceilings are not. Plenum rated
wire is typically more costly than non-plenum. Choose the correct
wire type based on your applicable local and national electrical codes.
For general reference, CBS wiring falls under NEC (National Electrical
Code) Class 2 type.