User Manual Chapter 3

Chapter 3: Installing the Hardware Infrastructure 3-19
Ethernet Hub. Standard 4 pair, CAT5, 24 AWG solid, unshielded,
plenum rated cables are required for all Ethernet communications.
1. Locate the Ethernet hub.
2. Cut a length of data cable that is long enough to reach from the hub
to the primary CBS.
3. On each end of the data cable, install the wires into an RJ45
connector as shown in the following illustration and then crimp the
connector onto the cable.
18959
To Ethernet Hub
or CBS III Hub
To CBS III
Hub
RJ45
Connector
Blue/White
Orange
Orange\White
Green
RJ45
Connector
8
1
1
8
Note: Colors shown are for recommended Belden
cables. Your wire colors may be different.
Blue/White
Orange
Orange\White
Green
Blue
Blue
Green/White
Green/White
Brown
Brown
Brown/White
Brown/White
Belden Wire Colors
RJ45 Pin Color RJ45 Pin Color
1Orange 5Blue
2 Orange/White 6 Green/White
3Green 7Brown
4 Blue/White 8 Brown/White
4. Plug the data cable into the Uplink data connector on the primary
CBS.