User's Manual

SPECIFICATION REV
497-0430074 A
12 OF 22
3.2 Environment Test Requirements
3.2.1. Temperature & Humidity
3.2.1.1 Operating
Operating temperature and humidity testing per NCR standard procedures is not applicable. This is hand-
held device that can not operate stand-alone and is intended for use in a conditioned environment.
3.2.1.2 Non-Operating
3.2.1.2.1 Storage
Min. Max. Note
Period of Storage Range - 3 months
Temperature Range (Dry Bulb) 10
o
C +50
o
C
Temperature Change - 15
o
C/Hr.
Relative Humidity Range 10 % 90 % No condensation
Barometric Pressure
70x10
3
Pa 105x10
3
Pa
A maximum of 2,000
meter altitude
3.2.1.2.2 Shipping
Min. Max. Note
Period of Storage Range - 3 months
Temperature Range (Dry Bulb) -40
o
C +60
o
C
Temperature Change - 15
o
C/Hr.
Relative Humidity Range 5 % 95 % No condensation
Barometric Pressure
70x10
3
Pa 105x10
3
Pa
A maximum of 2,000
meter altitude
3.2.2. Shock and Vibration
3.2.2.1 Operating
Operating temperature and humidity testing per NCR standard procedures is not applicable. This is hand-
held device that can not operate stand-alone and is intended for use in a conditioned environment.