User's Manual

D-POS User Manual NE41 07105-02 v1.0
3.5 LED Indicaon
There are three light eming diodes (LED) in D-POS. The acvity LEDs - LED1 and
LED2 - are red. The power LED - LED3 - is green. When the D-POS unit is powered
on, all three LEDs light up for one second. LED3 burns with a steady green light as
long as the power supply is OK and the D-POS unit is working without problems.
When the unit is working correctly, LED1 is blinking when antenna 1 is transmit-
ng and LED2 is blinking when antenna 2 is transming.
If LED3 is blinking with a green light, an error has been detected with the power
supply or the antennas, or the D-POS unit is broken or the lid is open (tamper
switch is open).
If LED1 is blinking with a red light and LED3 is blinking with a green light, there is
a problem with antenna 1. If LED2 is blinking with a red light and LED3 is blinking
with a green light, there is a problem with antenna 2.
3.6 LOOP Antenna
A LOOP Antenna is an electrical cable in a loop creang an electrical eld. Max
cable length <10 meters and cable area >0.4 mm
2
(AWG 21).
4 Installaon
1. To change the conguraon of D-POS, remove the lid and make sure the
AC/DC adapter is unplugged. Change the sengs of rotary switches, DIP
switches and jumpers as described on page 6 in this manual.
2. Connect a D-POS ANT to screw terminals 1 & 2 OR a LOOP antenna to screw
terminals 2 & 3.
To use both D-POS ANT and a LOOP Antenna connect D-POS ANT to screw
terminals 4 & 5 and then the LOOP Antenna to screw terminals 2 & 3.
3. If a magnec contact switch is used, connect it to screw terminals 8 & 10.
4. If the RFID eld from two D-POS units overlap, connect a synchronizaon cable
to screw terminals 9 & 10 on both D-POS units.
5. Connect the AC/DC adaptor to screw terminals 6 & 7.
Only use AC/DC adaptor provided by NEAT or use 12-24 V
DC
as central
power supply.
6. Close and fasten the lid using the screws supplied.
7. Plug in the AC/DC adaptor in a mains outlet in the apartment.
8. The power LED lights up with a steady green light to indicate power is on.
To adjust the rotary switches we recommend a at screwdriver with a 2.4 x 0.5
mm blade. Use max. 10 meters of cable with cable area 0.4 mm
2
or more (AWG
21) for ferrite and loop antennas.