User's Manual Part 1

ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-21
Note 1: It is not possible to change capacity between OC-3 and Ethernet under working
condition.
Note 2: In MAINT status, excepting HK-OUT and Cluster ALM, alarm outputs are masked
to normal condition.
Note 3: The summarization of alarm outputs is fully user programmable; The sign in
above table shows fixed item and can not be changed. The sign only shows the
factory settings. The sign output can be assigned for plural items. The sign
input/output can not be assigned. Either HK output or Cluster ALM output
in each channel can be assigned.
Note 4: Above Table shows Alarm output matrix for 1+1 configuration
Note 5: Only apply to SONET system.
Note 6: Only apply to XPIC system.
Note 7: Assign to relays 3 to 6 only one category, either NLite E Alarm, House Keeping
Control out or Cluster Alarm out.
Output Port condition
Interface circuit: Relay Form C
Maximum Current: 0.2 A
Maximum Voltage: 100 V (AC+DC)
Event/ Alarm Open
(Normally closed)
Event/ Alarm Close
(Normally open)
COM
Relay
33 INTFC (1/2) LAN
LINK PORT
Loss of SC LAN Link IDU INTFC
<Note5>
34 XCTRL ALM1 Control failure or REF
Signal failure
IDU INTFC
<Note6>
35 XCTRL ALM2 Control failure or REF
Signal failure
IDU INTFC
<Note6>
36 XREF ALM1 Control failure or REF
Signal failure
IDU INTFC
<Note6>
37 XREF ALM2 Control failure or REF
Signal failure
IDU INTFC
<Note6>
38 HK-OUT1 House keeping Control out1 Only show
PNMT
39 HK-OUT2 House keeping Control out2 Only show
PNMT
40 HK-OUT3 House keeping Control out3 Only show
PNMT
41 HK-OUT4 House keeping Control out4 Only show
PNMT
42 Cluster ALM out1
This item received from
opposite site. Item 1
Only show
PNMT
43 Cluster ALM out2
This item received from
opposite site. Item 2
Only show
PNMT
44 Cluster ALM out3
This item received from
opposite site. Item 3
Only show
PNMT
45 Cluster ALM out4
This item received from
opposite site. Item 4
Only show
PNMT
Table 2-6 Alarm & House Keeping Output Items (Cont’d)
#
Alarm Item
displayed
on LCT/PNMT
Condition
ALM LED
Indication
(IDU’s front)
Summarized Alarm Output
(Form-C) <Note 1,2,3,7>
RL1 RL2 RL3 RL4 RL5 RL6