User's Manual Part 2

ROI-S05750 INSTALLATION
2-29
Chart 2-6 (Cont’d)
Step Procedure
CHANGE OF POLARIZATION
ODU DIRECT MOUNTING TYPE ANTENNA
(Example (RFS))
Note: The details are referred to the installation manual which
is attached to the antenna. The installation or removal of
the antenna requires qualified experienced personnel.
Note: The antenna is set to V-polarization when shipped from
the factory.
RFS SB1
1. Unscrew the 4 screws M3 at the refined
steel ring,
2. Hold the feed tightly at the waveguide,
3. Rotate carefully the feed 90 degrees,
4. Mount the feed to the refined steel ring
and lock the 4 screws M3.
1. Loosen the 4 screws M3,
2. Hold the feed tightly at the waveguide,
3. Rotate the casting plate carefully the
feed 90 degrees,
4. Lock the 4 screws M3.
RFS C-Mount
Drain Plug
Drain Plug
4 screws (M3)
Polarization V
Polarization H