ROI-S05750 INSTALLATION
2-63
Chart 2-11 (Cont’d)
Step Procedure
6 Insert the O-rings to the two ODU ports of the OMT (see figure
in step 9),
7 Insert the guide pin into the hole of the OMT and set the
position of screws,
8 Confirm which polarization is applied to the Master ODU.
Check the indication of polarization on the upper side of OMT.
9 Fix the two ODUs with hex screws (four locations) using the
allen key wrench,
Note: Be careful not to damage the O-rings.
GUIDE PIN
O-ring
ODU
O-ring
ODU
ODU
HEX SCREW
H
POLARIZATION
SIDE
V
POLARIZATION
SIDE
HEX SCREW
Note: Tightening torque is 4.0 N·m ± 10%.