User's Manual Part 3

INSTALLATION ROI-S05750
2-86
Chart 2-16 (Cont’d)
Step Procedure
8 Mount the contact onto the center conductor and mount the
insulator onto the contact.
INSULATOR CONTACT
9 Insert the cable into the shell.
10 Tighten the tying metal by wrench using the wrench points.
(Tighten with torque of 4 to 10 N·m)
WRENCH POINT
LESS THAN 0.1 mm