User's Manual Part 3

INSTALLATION ROI-S05750
2-80
Chart 2-15 Terminating IF Coaxial Cable with TNC-P
Connector (L Angle Type) (HIROSE made)
us
ed for IDU IF IN/OUT
Step Procedure
Note: It is recommended that TNC (Male) L-angle connector for the
8D-FB IF cable is used to connect it to the IDU. When the N
(Male) straight connector is attached to the 5D-FB or 10D-FB
IF cable, use of the TNC (Male) - N (Female) (NJ-TNCP-LA)
L-angle adapter is needed.
1 Pass the tightening nut, the washer and the ga
sket on the cable in
the order shown in the figure.
Then, strip the cable jacket in the diameter show
n in the figure.
[Applicable cable : 8D-FB-E]
Note: Be careful of insertion direction for the gasket and the tightening nut.
Note: Be careful not to dama
ge the outer conductor.
Note: Do not reuse the gasket because the clamp deforms
it after
tightening.
2 Insert the clamp to clamp the strippe
d cable jacket end. Open the
end of the outer conductor a little,
3 Insert the hood between the plastic tape with
aluminium foil and
the outer conductor,
Clamp
Hood
Note: Use the insertion stick to open the hole of about
φ
9. No gap is
allowed in between the clamp, the outer conductor and the hood.