User's Manual Part 3

INITIAL LINE UP ROI-S05750
3-5
Chart 3-1 (Cont’d)
Step Procedure
Note: 1 The ODU power is supplied from the IDU
DC Power Connection-2 (DC-DC CONV)
1+0 SYSTEM
1 Check that the IF cable between the MODEM and the ODU is
connected,
2 Connect the power cable to 43 V/OUT of the DC DC CONV
and SELV of the MODEM as shown in Fig 3-1 (2/2),
3 Before connecting the power cable connector to the SELV
of the DC-DC CONV, check that the rated input voltage
is 24V/48V (allowable range; within
20 to 60 V) or
+24V/+48V (allowable range; within
+20 to +60 V) with
the digital multimeter, (see Fig. 3-1),
4 Pull out the PWR switch lever of the DC-DC CONV and turn
on,
5 Confirm that the PWR indicator on the DC-DC CONV is ON,
6 Pull out the PWR switch lever of the MODEM and turn on,
7 Confirm that the PWR indicator on the MODEM is ON.
1+1 SYSTEM
1 Check that the IF cable between the No.1 MODEM and the No.
1 ODU, is connected,
2 Connect the power cable to 43 V/OUT of the No.1 DC DC
CONV and SELV of the No.1 MODEM as shown in Fig 3-1 (2/
2),
3 Before connecting the power cable connector to the SELV
of the DC-DC CONV, check that the rated input voltage
is 24V/48V (allowable range; within
20 to 60 V) or
+24V/+48V (allowable range; within
+20 to +60 V) with
the digital multimeter, (see Fig. 3-1),
4 Pull out the PWR switch lever of the No.1 DC-DC CONV and
turn on,
5 Confirm that the PWR indicator on the No.1 DC-DC CONV is
ON,