User's Manual Part 4

ROI-S05752 Provisioning
-51-
Condition for TX/RX SW (only for 1+1 configuration)
13 Click on the “Condition for TX/RX SW” sub-menu button in
“Provisioning”,
14 Click on the control button of required control mode for the TX
SW and the RX SW,
Notes: 1 TX SW control mode is applied only for Hot Standby
configuration.
2 For TX and RX SW Priority, select Non Priority for Non-
revertive operation at TX or RX alarm condition is restored.
3 Manual mode of RX SW Maintenance Mode, disables the RX
SW operation under either No. 1 or No. 2 RX route is alarmed.
4 Forced mode of RX SW Maintenance Mode, enables the RX
SW operation through either or both No. 1 or No. 2 RX route
is alarmed.
5 Early Warning provides less than 1E
-9
.
Condition for APS
15 Click on the control button of required setting mode for the
APS,
Note: For the details of Condition for APS setting, see the Automatic
Protection Switching (APS) in the Section II Operation.
----Condition for TX/RX SW---
TX SW Priority Non Priority Priority No.1
RX SW Priority Non Priority Priority No.1
RX SW Maintenance Mode Manual Forced
RX SW Condition-Early Warning Included EW Excluded EW
----Condition for APS---
APS Maintenance Mode Manual Forced
APS Condition-SF(PROT) Priority High Priority Low
APS Condition-SD(B1) Included SD Excluded SD
Lock in Usage Not Used Used
Lock in Count (times) 4 1 to 255
Lock in Detect Time(min) 10 1 to 60
Lock in Hold Time(min) 24 1 to 48