Fig. 3-4 ATPC, Functional BLock Diagram
Example of ATPC setting.
Where ATPC MAXIMUM PWR of ATPC Range is set to 0 dB, ATPC
MINIMUM PWR is set to -10 dB and RX Threshold to -55 dBm. In this
case, if RX level is lower than -55 dBm, monitor/control is performed with
the interval of 8 msec. RX level is monitored in 1 dB step, and TX output
is controlled in 1 dB step.
However, a fixed hysteresis of 5 dB referred to the RX Threshold is
implemented for ATPC operation.
Example: If RX Threshold is set to -55 dBm, no output control is made
unless the RX level goes below -55 dBm or goes above -50 dBm, so that
the receive level is maintained within -55 to -50 dBm by ATPC.