CORRECTIVE MAINTENANCE ROI-S05751
5-44
Chart 5-4 (Cont’d)
Step Procedure
6 When the MAINT LED blinks, insert the MMC into the MMC
slot on the CTRL front, which has equipment configuration data
used in the former CTRL,
7 The download of the equipment configuration data start, the
de
ployment is performed. When the CTRL has been made
provision, MAINT LED on the IDU turns to light. Check that
the MAINT LED lights and set the PROTECT SW to OFF
position (for lower side). Then, the equipment configuration
data deploys and data is restored.
8 In the Equipment Setup menu and the Provisioning menu,
confirm that the equipment configurati
on and setting conditions
are the same as before replacement. Check that neither alarm is
indicated in the Alarm Status.
9 The CTRL replacement finishes. Perform the resetup for the
Network
Config. since the Network Config. data is not restored.