This appendix describes the general configuration procedures for iPasolink network element.
Switch ON Node and PC Configuration
1. Switch ON the Node, wait for at least 7 minutes for the node to completely come-up (before
trying to ping or access the node (through browser).
2. The Factory default IP address for NEC Multiplexer is 192.168.1.254 or the one, which is
present on the sticker pasted on the Node.
3. Use a PC/Laptop and configure the PC/laptop
IP Address to: Replace the IP address in the 192.168.1.0 network
Subnet Mask to: 255.255.255.0
4. Connect the PC to the NMS/LCT interface of the multiplexer using a cross RJ-45 NMS
cable.
Logging into the System
To logging into the system, perform the following steps:
1. Connect the Ethernet port of PC/Laptop to the NMS port of the network element using a
cross cable. Use straight cable only, if both the Node and PC/Laptop are connected through
Hub/Switch.
2. Open the Internet Explorer in the Windows PC. Enter the address in the address space:
http://192.168.1.254:20080.
3. Log into the WUI with following user name and password.
User Name: NEC Corporation
Password: j72e#05t
4. Configuration:
Name: Enter the Name of the Site/Location.
Acceptable Values: combination of alphabets/numeric/special characters
Value Range: 1-22
Router ID: Enter the Router ID (Ex:192.168.254.1)
Ethernet IP: Enter the Ethernet IP of the iPasolink node (Ex:192.168.1.254)
Contact: Enter the contact details
Appendix II
General Configuration