iPasolink250 Installation and Commissioning Guide Document ID: 141-DOC000008-E
Location: Enter the location name
5. Submit changes and Accept the Modifications. The network element will go for a soft reboot
if values of Ethernet IP and Router ID are changed and after 3 minutes, you can login to the
system. If you are connecting other vendor Node to the local Node, then set the Remote
node with the router ID and Ethernet IP as follows:
Router ID: Enter the Router ID (Ex: 192.168.254.2)
Ethernet IP: Enter the Ethernet IP of the other vendor's node (Ex: 192.168.2.254)
Figure below illustrates PC connected to the node in a network.
Configuring OSPF Parameters
To configure OSPF parameters:
1. Click Configuration > DCN > OSPF in the navigation menu. OSPF Parameters configuration
page is displayed with default Ospf area configured as 0.0.0.1.
2. Enter value for area if different from default area address mentioned above.
3. Click Submit. A confirmation page is displayed.
4. Click Accept Valid Modifications. A "Successfully Modified" message is displayed.
Configuring E3/DS3 Ports
To provision PDH ports,
1. Click Configuration > Facilities > DS1/DS3 in the Navigation menu.
2. Click DS1/DS3 in the sub menu. DS1/DS3 Interface configuration preview pane is
displayed.
3. Click the desired DS1/DS3 port. Provision interface preview pane is displayed.
4. Select/Enter values referring to the PDH Interface Parameters table.
5. Click Submit. A confirmation message is displayed.
Figure 24: PC connected to the Node