Technologies PlasmaSync Plasma Monitor User's Manual 42/50PD1

13
Side View.... Terminal Board L/R
10
11
12
13
AC-IN
OUT
IN
RGB1
HIGH 75
RGB2
VIDEOG B H/CS
V
R S-VIDEO
10 DIP SW
Sets the various modes of this unit.
11 RGB3 (DVI 29pin)
IN connector: Inputs a digital RGB signal. (TMDS)
Note:
This connector does not support analog input.
12 REMOTE (Mini jack)
IN jack: This jack connects the wired remote control.
THROUGH OUT jack: Outputs as is the remote
control signal that is connected to the REMOTE IN
jack.
* This is used when operating multiple monitors (i.e., of
this unit) with a single remote control.
13 EXTERNAL CONTROL (mini D-Sub 15 pin)
Controlled by the computer’s RS-232C interface.
IN connector: Used when operating this unit with
EXTERNAL CONTROL from a personal computer.
THROUGH OUT connector: Outputs as is the signal
that is input to the EXTERNAL CONTROL IN
connector.
14 CONTROL LOCK
When “CONTROL LOCK” is set to “ON”, the buttons
on the set’s control panel do not function.
14
15
16
17
18
15 VIDEO
IN [BNC] connector (BNC): Inputs the video
(composite video signal).
IN [S] connector (DIN 4 pin): Inputs the S video (Y/
C separate signal).
* When connections are made to both the BNC connector
and the S video connector, the signal of the S video
connector has priority.
THROUGH OUT [BNC] connector (BNC): Outputs
as is the signal that is input to the VIDEO IN [BNC]
connector.
THROUGH OUT [S] connector (DIN 4 pin): Outputs
as is the signal that is input to the VIDEO IN [S]
connector.
16 RGB2 [R, G, B, H/CS, V] (BNC)
IN connector: Inputs the analog RGB signal.
The H/V composite signal is connected to the H/CS
connector.
THROUGH OUT connector: Outputs as is the signal
input to the RGB2 IN connector.
75/HIGH switch: This switch selects the impedance
of the connector. It is usually used in the “75” position.
17 RGB1 (mini D-Sub 15 pin)
IN connector: Inputs the analog RGB signal of a
personal computer, etc.
18 AC IN connector
Connects with the supplied power cable.
Insert the prongs completely.
* for PLUGGABLE EQUIPMENT, tee
socket-outlet shall be installed near the
equipment and shall be easily accessible.