EXTERNAL CONTROL
Pin No.
1 to 3
4
5 and 14
6 to 8
9 and 10
11
12
13
15
Function
Not used
Power ON/OFF
Open
ON
Established
OFF
Input switching
The input mode is switched by the combination of pin num-
bers 5 and 14.
Not used
Ground
TXD (RS-232C)
RTS
RXD (RS-232C)
CTS
Input Pin No. 5 Pin No. 14
VIDEO Open Open
RGB1 Ground Open
RGB2 Open Ground
RGB3 Ground Ground
Application
These specifications are applicable to NEC plasma monitors (including 42- and 50-inch types) and communications con-
trol from external equipment.
Connections
Connections should be made as described below.
1) Display-side connector: EXTERNAL CONTROL connector
*A maximum of 4 units can used with a cascade connection.
External equipment
e.g., Personal computer
2) External equipment side connector: Serial port (RS-232C) connector
See the specifications of the connected equipment for information about the type of connector and pin assignment.
Function and Pin Configuration of the External Control Connector