User Manual
Table Of Contents
- DECLARATION OF CONFORMITY
- Important Information
- Safety Precautions, Maintenance & Recommended Use
- Installation
- Parts Name and Functions
- Setup
- Connections
- Basic Operation
- OSD (On-Screen-Display) Controls
- Remote Control Functions
- Multiple Monitors Connection
- Controlling the LCD monitor via RS-232C Remote Control
- Controlling the LCD monitor via LAN Control
- POINT ZOOM
- PROOF OF PLAY
- INTELLIGENT WIRELESS DATA
- MULTIPICTURE matrix
- Video out
- Features
- Troubleshooting
- Specifications - C751Q
- Specifications - C861Q
- Specifications - C981Q
- Manufacturer’s Recycling and Energy Information
- [Notice] About the MPEG-4 AVC, MPEG-4 Visual license included in this product
English-60
PROOF OF PLAY
This function allows to sending of messages for the current status of the monitor by self-diagnosis.
Check item Message
①
INPUT DisplayPort1, DisplayPort2, HDMI1, HDMI2, HDMI3, OPTION*, MP
②
Resolution ex. (H)1920, (V)1080 , (H)1360, (V)768 or No signal or Invalid signal
③
AUDIO INPUT IN, DisplayPort1, DisplayPort2, HDMI1, HDMI2, HDMI3, OPTION*, MP
④
Audio signal Audio in or No Audio in or N/A (IN, OPTION (analog)*)
⑤
Picture Image Normal Picture or No Picture
⑥
AUDIO OUT Normal Audio or No Audio
⑦
TIME (year)/(month)/(day)/(hour)/(minutes)/(second)
h
EXPANSION DATA
00h: Normal Proof of Play event
01h: Proof of Play event is “last power on time”
10h: MEDIA PLAYER is stop
11h: MEDIA PLAYER is start
12h: MEDIA PLAYER is pause
13h: MEDIA PLAYER error occur
20h: Contents Copy from USB
21h: Contents Copy form network folder
30h: Contents Copy Success
31h: Contents Copy Error (No media)
32h: Contents Copy Error (Connect error)
33h: Contents Copy Error (Out of disk space)
34h: Contents Copy Error (Read/Write error)
40h: Human detected (Human sensor Status)
41h: Human detect cleared (Human Sensor Status)
*: This function depends on which option board you are using.
Example:
①
HDMI1
②
1920 x 1080
③
HDMI1
④
IN1
⑤
Normal Picture
⑥
Normal Audio
⑦
2014/1/1/0h/0m/0s
h
10h: MEDIA PLAYER is stop
NOTE: For the Proof of Play function, please see the “External_Control.pdf” on the CD-ROM supplied with this monitor.