ND-45504 (E) ISSUE 2 PART OF STOCK # 151900 ® Circuit Card Manual DECEMBER, 1997 NEC America, Inc.
LIABILITY DISCLAIMER NEC America Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America Inc. and shall not be reproduced without prior written approval from NEC America Inc. NEAX and Dterm are registered trademarks of NEC Corporation. Copyright 1997 NEC America Inc. Printed in the U.S.A.
PAGE No. ADD. No. 001 i 002 003 004 005 006 007 008 2.2 ii 2.1 PAGE No. 36 2.2 iv 38 1 39 40 2.2 4 2.1 42 5 2.1 43 6 44 7 45 004 005 006 007 008 2.1 2.2 2.2 46 9 2.2 47 10 2.2 48 11 2.2 49 12 2.2 50 13 14 51 2.1 52 15 53 16 54 17 55 18 56 19 57 20 2.2 59 22 60 23 61 24 62 25 63 26 64 27 65 28 29 2.1 30 31 65-1 2.1 65-2 2.1 65-3 2.1 2.2 65-4 2.1 2.2 66 33 2.2 67 34 2.2 32 2.1 58 21 2.
PAGE No. ADD. No. 001 002 003 004 005 006 007 008 PAGE No. 68-1 2.1 97 68-2 2.1 98 68-3 2.1 99 68-4 2.1 100 69 2.1 102 71 2.1 103 72 104 73 105 74 106 75 107 76 108 77 109 78 002 003 004 005 006 007 008 110 2.1 111 78-2 2.1 112 78-3 2.1 113 78-4 2.1 114 78-5 2.1 115 78-6 2.
ND-45504 (E) ISSUE 2 DECEMBER, 1997 NEAX2000 IVS Circuit Card Manual TABLE OF CONTENTS Page LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . 52 PN-AP00-A (AP00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 PN-AP01 (AP01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 PN-BRTA (BRI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIST OF FIGURES Figure 3-1 3-2 3-3 3-4 3-5 3-6 4-1 4-2 Title Page Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 MP/FP Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 MP/FP Card Mounting Slots for Back up MP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIST OF TABLES Table 2-1 2-2 2-3 4-1 4-2 4-3 Title Page Functional Outline of Control Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Outline of Application Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Outline of Line/Trunk Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table of Control Circuit Cards . . . . . . . . . . . . . . . .
CHAPTER 1 INTRODUCTION 1. PURPOSE For installers and maintenance technicians of the NEAX2000 IVS (PBX), this manual explains the functional outline and installation conditions of the circuit cards, and explains the meaning of each indicator lamp (LED) and the switch settings on the circuit cards. 2. OUTLINE OF THE MANUAL This manual consists of four chapters. The contents of Chapter 2 through 4 are as outlined below.
This page is for your notes. CHAPTER 1 Page 2 Revision 2.
CHAPTER 2 FUNCTIONAL OUTLINE OF CIRCUIT CARDS This chapter explains the functional outline of various circuit cards used in the NEAX2000 IVS. Explanations are given in alphabetical order of the circuit card names for each kind (Control, Application, and Line/Trunk) of circuit cards. 1. CONTROL CIRCUIT CARDS Table 2-1 shows the functional outline of each control circuit card.
Table 2-1 Functional Outline of Control Circuit Cards (Continued) CARD NAME PZ-PW86/ PZ-PW86-A PZ-PW86(C) PZ-PW86(D) FUNCTIONAL NAME FUNCTIONAL OUTLINE PWR Main power supply card. Input: AC100 V/200 V (50 Hz/60 Hz) Output: –27 V (8 A), +5 V (8.5 A), CR (30 mA) One card per PIM. PWR Main power supply card. Input: AC100 V/200 V (50 Hz/60Hz) Output: –27 V (4.5 A), +5 V (7.5 A), CR (30 mA), +80 V (110 mA) One card per PIM. PWR Main power supply card.
Table 2-2 Functional Outline of Application Circuit Cards (Continued) FUNCTIONAL NAME FUNCTIONAL OUTLINE ETHER Ethernet Control card. This card is used with the PN-AP01 card to accommodate the Ethernet, transmitting/receiving a signal of TCP/IP protocol. 10 BASE-T twisted pair cable can be connected directly to this card. PN-CK00 PLO Phase Locked Oscillator card. This card is a phase locked oscillator for providing a synchronized clock signal with the network.
3. LINE/TRUNK CIRCUIT CARDS Table 2-3 shows the functional outline of each line/trunk circuit card. Table 2-3 Functional Outline of Line/Trunk Circuit Cards CARD NAME FUNCTIONAL NAME FUNCTIONAL OUTLINE PN-2AMPA AMP 2-line Amplifier Trunk card. This card is equipped with the functions of Echo Canceller (EC), Automatic Gain Controller (AGC) and Tone Disabler (TD). PN-AUCA AUC 2-line Long-Line circuit card provided with the Power Failure Transfer (PFT) function.
Table 2-3 Functional Outline of Line/Trunk Circuit Cards (Continued) FUNCTIONAL NAME FUNCTIONAL OUTLINE DLC 4-line Digital Line Circuit card for Dterm Series E/Series III/ElectraPro/DSS Console. [–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)] This card is equipped with quick diagnostics to detect short line conditions and the normality (Synchronous/Asynchronous) of the terminal. PN-4DLCD DLC 4-line Digital Line Circuit card exclusively used for D term Series E/Series III.
Table 2-3 Functional Outline of Line/Trunk Circuit Cards (Continued) FUNCTIONAL NAME FUNCTIONAL OUTLINE PN-4LCJ LC 4-line Analog Line Circuit card for single line telephones. This card provides 4 circuits with Disconnect Supervision. Loop resistance: Max. 600 ohms. This card is equipped with quick diagnostics to detect short and open line conditions. PN-M03 M03 V.35 DTE interface card. This card is used together with the PN-2DPCB card to provide the V.35 interface.
CHAPTER 3 CIRCUIT CARD INSTALLATION CONDITIONS This chapter explains the conditions for installing various kinds of circuit cards used in the PBX. 1. CIRCUIT CARD MOUNTING SLOTS Figure 3-1 below shows circuit card mounting slots allocated in the PIM based on circuit card type.
BUS/AP8 MP0 MP1 LT14/AP4 LT15/FP/AP5 LT13/AP3 LT12/AP2 LT11/AP1 LT10/AP0 LT09 LT08 LT07 LT06 LT05 LT04 LT03 LT02 LT01 LT00 PIM(H)0 PWR *1 *2 *3 BUILT-IN BATTERY LT00 - LT15 AP0 - AP8 MP0, MP1 FP BUS PWR : : : : : : Line/trunk circuit card mounting slots Application circuit card mounting slots PN-CP02/PN-CP02-C mounting slot PN-CP01 mounting slots PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B mounting slot PZ-PW86/PZ-PW86-A/PZ-PW86 (C)/(D) mounting slot *1 Either line/trunk circuit car
2. INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS 2.1 PN-CP00/PN-CP00-B/PN-CP00-C (MP) Mount the PN-CP00/PN-CP00-B/PN-CP00-C in the MP slot of PIM0. 2.2 PN-CP01 (FP) 1. The PN-CP01 is required only if any of the following is true. • More than one PIM is used. • A PN-2DLCC is used. • A PN-AP01 is used. • OAI, ACD, No. 7 CCIS or ISDN is used. 2. When the system is equipped with two PIMs, mount one PN-CP01 in the FP slot of PIM0.
2.3 PN-CP02/PN-CP02-C (MP) Mount the PN-CP02/PN-CP02-C in the MP0 and MP1 slot of PIM(H)0. This card is used only for Back up MP system. PIM3 PIM7 F P PIM2 F P PIM1 PIM(H)0 PIM5 F P M P 1 M P 0 F P Figure 3-3 MP/FP Card Mounting Slots for Back up MP System CHAPTER 3 Page 12 Revision 2.
2.4 PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01) 1. In a one-PIM system, neither the PN-BS00-A/PN-BS00-B nor the PN-BS01-A/PN-BS01-B is needed. 2. When the system is equipped with more than one PIM, mount a PN-BS00-A/PN-BS00-B in the BUS slot of PIM0 or PIM(H)0. 3. When the system is equipped with more than one PIM, mount one PN-BS01-A/PN-BS01-B in the BUS slot of PIM1 through PIM7, as required.
3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS 1. When the system is equipped with only one PIM: • An application circuit card can be mounted in the AP0 through AP6, and AP8 slots. • An application circuit card can not be mounted in the AP6 slot if any of the following is true. – A PN-2DLCC is used. – A PN-AP01 is used. – OAI, ACD, No. 7 CCIS or ISDN is used. – The PN-CP02s are used. 2.
BUS/AP8 MP/FP/AP7 PIM0-7 FP/AP6 AP5 AP4 AP3 AP2 AP1 AP0 LT SLOTS (00-09) PWR * BUILT-IN BATTERY • Line/trunk circuit cards can also be mounted in AP0 - AP5 slots. MP0 BUS/AP8 AP5 MP1 AP4 AP3 AP2 AP1 AP0 LT SLOTS (00-09) PIMH (0) PWR * BUILT-IN BATTERY • Line/trunk circuit cards can also be mounted in AP0 - AP5 slots. Figure 3-5 Application Circuit Card Mounting Slots ND-45504 (E) CHAPTER 3 Page 15 Revision 2.
4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS Mount the line/trunk circuit cards in the LT00 through LT15 slots of PIM0/PIM(H)0 through PIM7. BUS/AP8 MP/FP/AP7 AP6 LT15 LT14 LT13 LT12 LT11 LT10 LT09 LT08 LT07 LT06 LT05 LT04 LT03 LT02 LT01 LT00 PIM0-7 PWR * BUILT-IN BATTERY • Application circuit cards can also be mounted in the LT10 through LT15 slots.
CHAPTER 4 LAMP INDICATIONS AND SWITCH SETTINGS This chapter explains various circuit cards used in the PBX with respect to the following items. Explanations are given in the alphabetical order of the circuit card names within each circuit card category (Control, Application, and Line/Trunk). 1. Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of each circuit card are shown by a face layout. 2.
1. PRECAUTION IN HANDLING When handling a circuit card, the installer must wear a grounded wrist strap to protect the circuit card from static electricity. • WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD PBX WRIST STRAP FRAME GROUND SCREW CONNECT THE GROUND WIRE TO THE FRAME EARTH OF THE EQUIPMENT. NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. • WHEN HOLDING A CIRCUIT CARD CARD FRONT Figure 4-1 Static Electricity Precautions (1 of 2) CHAPTER 4 Page 18 Revision 2.
• WHEN SETTING SWITCHES ON A CIRCUIT CARD CIRCUIT CARD WEAR A WRIST STRAP AND PERFORM THE WORK STANDING ON A GROUNDED CONDUCTIVE WORK SURFACE. • WHEN CARRYING A CIRCUIT CARD CIRCUIT CARD CONDUCTIVE POLYETHYLENE BAG WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN THE CONDUCTIVE POLYETHYLENE BAG. Figure 4-1 Static Electricity Precautions (2 of 2) ND-45504 (E) CHAPTER 4 Page 19 Revision 2.
CAUTION The installer must hold the edge of circuit card, when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. PBX NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BASE HANDS. CARD FRONT Figure 4-2 Circuit Card Handling Precautions CHAPTER 4 Page 20 Revision 2.
2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS Table 4-1 below shows the control circuit cards to be explained in this section.
PN-BS00-A/PN-BS00-B (BS00) PN-BS00-A/PN-BS00-B (BS00) 1. Locations of Lamps, Switches, and Connectors MB CN2 CN1 PN-BS00-A/PN-BS00-B (BS00) Card 2. Lamp Indications This card has no indicator lamps. CHAPTER 4 Page 22 Revision 2.
PN-BS00-A/PN-BS00-B (BS00) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION MB (Toggle SW) FUNCTION CHECK For make-busy ON UP For normal operation DOWN Note The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.
PN-BS01-A (BS01) PN-BS01-A (BS01) 1. Locations of Lamps, Switches, and Connectors MB CN2 SW13 CN1 PN-BS01-A (BS01) Card 2. Lamp Indications This card has no indicator lamps. CHAPTER 4 Page 24 Revision 2.
PN-BS01-A (BS01) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER MB (Toggle SW) SETTING POSITION UP ON FUNCTION CHECK For make-busy For normal operation DOWN Note SW13 (Dip SW) ON 1, 5 OFF ON 1 2 3 4 5 6 7 8 Set SW13 according to the mounting location of this card. ON 2, 6 OFF ON 3, 7 OFF ON 4, 8 OFF MOUNTING LOCATION PIM1 PIM2, PIM3 PIM4, PIM5 PIM6, PIM7 SWITCH SW13 No.
PN-BS01-B (BS01) PN-BS01-B (BS01) 1. Locations of Lamps, Switches, and Connectors SW0 MB CN2 CN1 PN-BS01-B (BS01) Card 2. Lamp Indications This card has no indicator lamps. CHAPTER 4 Page 26 Revision 2.
PN-BS01-B (BS01) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SW0 (Rotary SW) SETTING POSITION FUNCTION CHECK Set this rotary switch to match the location in which this circuit card is to be mounted.
PN-CP00 (MP) PN-CP00 (MP) 1. Locations of Lamps, Switches, and Connectors SW3 RUN SW1 SW2 CLKIN JP0 RS PN-CP00 (MP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green Flashes at 120 IPM while the circuit card is operating normally. CLKIN Green Lights while receiving clock signals to the PLO oscillator. CHAPTER 4 Page 28 Revision 2.
PN-CP00 (MP) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION SW3 (Rotary SW) 0 On Line (Call processing is in progress) 2 Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3 Off Line (Call processing is stopped) • I/O port: 1200 bps (Fixed) B For clearing the office data C For setting the resident system program 0 0~F Note FUNCTION 1, 4 ~ 9 A, D ~ F SW1 (Push SW) CHECK Not used For initializing the CPU SW2 (Piano Key SW) ON KF Mod
PN-CP00 (MP) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SW2 (Piano Key SW) SETTING POSITION FUNCTION CHECK • When using the PLO card (PN-CK00): OFF 2, 3 SW2-2 OFF SW2-3 ON 4 • When not using the internal PLO and the PLO card: SW2-2 SW2-3 OFF OFF 3 2 1 ON 4 OFF Not used JP0 (Jumper pin) LEFT For factory testing Front RIGHT For normal operation JP2 (Jumper pin) UP DOWN For normal operation Memory backup connected For factory test only Disconnect battery The figure in the
PN-CP00-B/PN-CP00-C (MP) PN-CP00-B/PN-CP00-C (MP) 1. Locations of Lamps, Switches, and Connectors SW3 RUN SW1 SW2 CLKIN [CP00-B] Note JP0 RS [CP00-C] Note JP0 Note: Location of JP0 is different between CP00-B and CP00-C. PN-CP00-B/PN-CP00-C (MP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally. CLKIN Green Lights while receiving clock signals to the PLO oscillator.
PN-CP00-B/PN-CP00-C (MP) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION SW3 (Rotary SW) 0 On Line (Call processing is in progress) 2 Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3 Off Line (Call processing is stopped) • I/O port: 1200 bps (Fixed) B For clearing the office data C For setting the resident system program 0 0~F Note FUNCTION 1, 4 ~ 9 A, D ~ F SW1 (Push SW) Not used For initializing the CPU SW2 (Piano Key SW) ON KF
PN-CP00-B/PN-CP00-C (MP) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SW2 (Piano Key SW) SETTING POSITION FUNCTION CHECK • When using the PLO card (PN-CK00): OFF 2, 3 SW2-2 OFF SW2-3 ON 8 • When not using the internal PLO and the PLO card: SW2-2 SW2-3 OFF OFF 7 6 5 4 3 2 1 4~8 OFF Not used UP For normal operation Memory backup connected ON JP0 (Jumper pin) DOWN Front For factory testing (Disconnect battery for memory backup.
PN-CP03/PN-CP03-C (MP) PN-CP03/PN-CP03-C (MP) 1. Locations of Lamps, Switches, and Connectors SW3 RUN SW1 SW2 JACK CLK JP0 JP1 VR RS1 RS0 PN-CP03/PN-CP03-C (MP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green Flashes at 120 IPM while the circuit card is operating normally. CLKIN Green Lights while receiving clock signals to the PLO oscillator. CHAPTER 4 Page 34 Revision 2.
PN-CP03/PN-CP03-C (MP) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SW3 (Rotary SW) SETTING POSITION 0 On Line (Call processing is in progress) 2 Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3 Off Line (Call processing is stopped) • I/O port: 1200 bps (Fixed) B For clearing the office data C For setting the resident system program 0~F Note FUNCTION 1, 4 ~ 9 A, D ~ F SW1 (Push SW) CHECK Not used For initializing the CPU SW2 (Piano Key SW) ON
PN-CP03/PN-CP03-C (MP) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SW2 (Piano Key SW) OFF 2, 3 4 3 2 1 SETTING POSITION FUNCTION CHECK • When using the PLO card (PN-CK00): SW2-2 SW2-3 OFF ON • When not using the internal PLO and the PLO card: SW2-2 SW2-3 OFF OFF ON When using RS1 port for built-in MODEM OFF When using RS1 port for RS-232C.
PN-CP01 (FP) PN-CP01 (FP) 1. Locations of Lamps, Switches, and Connectors SW1 RUN MB PN-CP01 (FP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green FUNCTION Flashes at 120 IPM while the circuit card is operating normally. ND-45504 (E) CHAPTER 4 Page 37 Revision 2.
PN-CP01 (FP) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION CHECK Set this rotary switch to match the location in which this circuit card is to be mounted.
PN-CP02/PN-CP02-C (MP) PN-CP02/PN-CP02-C (MP) 1. Locations of Lamps, Switches, and Connectors SW3 RUN SW1 SW2 CLKIN STBY [CP02] Note JP0 SW4 MT RS [CP02-C] Note JP0 Note: Location of JP0 is different between CP02 and CP02-C. PN-CP02/PN-CP02-C (MP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green • Flashes at 120 IPM while the circuit card is active status and operating normally. • Flashes at 30 IPM or 15 IPM while the circuit card is stand by status.
PN-CP02/PN-CP02-C (MP) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION SW3 (Rotary SW) 0 0~F Note 2 Note 1 FUNCTION 0 On Line (Call processing is in progress) 2 Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3 Off Line (Call processing is stopped) • I/O port: 1200 bps (Fixed) B For clearing the office data C For setting the resident system program 1, 4 ~ 9 A, D ~ F Not used SW1 (Push SW) For initializing the CPU SW2 (Piano Key S
PN-CP02/PN-CP02-C (MP) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SW2 (Piano Key SW) SETTING POSITION FUNCTION CHECK • When using the PLO card (PN-CK00): SW2-2 SW2-3 OFF ON OFF 2, 3 8 • When not using the internal PLO and the PLO card: SW2-2 SW2-3 OFF OFF 7 6 5 4 3 4~7 2 OFF Not used ON Allowed to use MAT OFF For normal operation (Not allowed to use MAT) UP For normal operation Memory backup connected 1 ON 8 Note 3 JP0 (Jumper pin) Front DOWN For factory test only (Dis
PN-PW00 (EXTPWR) PN-PW00 (EXTPWR) 1. Locations of Lamps, Switches and Connectors RUN MB CONN PN-PW00 (EXTPWR) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green CHAPTER 4 Page 42 Revision 2.
PN-PW00 (EXTPWR) (3) Switch Setting Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION MB (Toggle SW) FUNCTION CHECK For make-busy (–48 V power off) UP ON For normal operation (–48 V power on) Note DOWN The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.
PZ-PW86 (PWR) PZ-PW86 (PWR) 1. Locations of Lamps, Switches, and Connectors SW102 MJ MJ MN MN ON ON ON 1 2 GND FG –27V GND FG –27V ON – OFF 100/120 240 SIDE VIEW FRONT VIEW PZ-PW86 (PWR) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR MJ Red Lights upon occurrence of a major trouble MN Yellow Lights upon occurrence of a minor trouble ON Green Remains lit while the operating power is being supplied CHAPTER 4 Page 44 Revision 2.
PZ-PW86 (PWR) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK Set to ON. 1 ON ON Standard setting (for equalize charging) 1 2 ON 2 Not used OFF SW For turning AC source power on I (ON) O (OFF) ON For turning AC source power off OFF AC INPUT: 90 V - 138 V 100/120 UP AC INPUT: 180 V - 276 V 240 DOWN The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch.
PZ-PW86-A (PWR) PZ-PW86-A (PWR) 1. Locations of Lamps, Switches, and Connectors SW102 SW102 MJ MJ MN MN ON ON ON 1 2 GND FG –27V GND FG –27V ON – OFF 100/120 240 SIDE VIEW FRONT VIEW PZ-PW86-A (PWR) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR MJ Red Lights upon occurrence of a major trouble MN Yellow Lights upon occurrence of a minor trouble ON Green Remains lit while the operating power is being supplied CHAPTER 4 Page 46 Revision 2.
PZ-PW86-A (PWR) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK SW102 PRESS MOMENTARILY 1 To start each PIM on battery power, when AC power is not provided (Switch “SW” must be ON). ON Set to ON. ON For float charging OFF Standard setting for equalize charging (Set to equalize for Gel cell or no battery.
PZ-PW86 (C) (PWR) PZ-PW86 (C) (PWR) 1. Locations of Lamps, Switches, and Connectors BATTERY START SW102 MJ MN ON ON 1 MODE 2 ON GND FG –27V 2 1 SW301 SIG SW1 BATT2 ON OFF BATT1 100/120VAC AC INPUT 240VAC SIDE VIEW FRONT VIEW PZ-PW86(C) (PWR) Card 2.
PZ-PW86 (C) (PWR) (3) Switch Settings Switch Settings SWITCH NAME MODE SWITCH NUMBER SETTING POSITION 1 OFF Always set to OFF ON Float charging, for sealed batteries (Normal Setting). OPTION: Periodic Equalize charging of external vented batteries. ON 1 2 2 OFF SW1 ON ON (I) FUNCTION CHECK Flaot charging, for vented batteries only.
PZ-PW86 (D) (PWR) PZ-PW86 (D) (PWR) 1. Locations of Lamps, Switches, and Connectors MJ MN ON ON 1 MODE 2 BATTERY START SW102 ON 2 1 GND FG –27V SW301 SIG (CN103) SIG (CN103) BATT2 100/120VAC BATT1 240VAC SW1 ON AC INPUT OFF SIDE VIEW FRONT VIEW PZ-PW86(D) (PWR) Card 2.
PZ-PW86 (D) (PWR) (3) Switch Settings Switch Settings SWITCH NAME MODE SWITCH NUMBER SETTING POSITION 1 OFF Always set to OFF ON Float charging, for sealed batteries (Normal Setting). OPTION: Periodic Equalize charging of external vented batteries. ON 1 2 2 OFF SW1 ON ON (I) FUNCTION CHECK Flaot charging, for vented batteries only.
3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS Table 4-2 below shows the application circuit cards to be explained in this section.
PN-AP00-A (AP00) PN-AP00-A (AP00) 1. Locations of Lamp, Switches, and Connectors MB J16 SENSE RUN MB SW1 WE L3 L2 L1 L0 RS3 RS2 RS1 RS0 SW0 PN-AP00-A (AP00) Card ND-45504 (E) CHAPTER 4 Page 53 Revision 2.
PN-AP00-A (AP00) (2) Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green WE Red FUNCTION Flashes at 120 IPM while this card is operating normally. Not used.
PN-AP00-A (AP00) (3) Switch Settings Switch Settings SWITCH NAME SENSE (Rotary SW) SWITCH NUMBER SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) to be set by CM05. 4-F AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-AP00-A (AP00) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION ON Enables the receive clock from the DCE (Modem) side when the No. 0 Port is synchronous. (Clock is received at the RXC terminal.) OFF • Uses the internal clock as the receive clock when the No. 0 Port is synchronous • When the No. 0 Port is asynchronous ON Enables transmit clock from the DCE (Modem) side when the No. 0 Port is synchronous. (Clock is received at the TXC (2) terminal.
PN-AP00-A (AP00) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION ON • Uses the internal clock as the receive clock when the No. 0 Port is synchronous. • When the No. 0 Port is asynchronous. OFF Enables receive clock from the DCE (Modem) side when the No. 0 Port is synchronous. (Clock is received at the RXC terminal) ON Set No. 0 port forcibly in a state which DSR signal is always provided. Force DSR signal high for port 0. No SMDR buffering.
PN-AP00-A (AP00) Note 1: Set the groove on the switch knob to the desired switch position. Note 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. Note 3: The SW 1 is used to select the AP operating mode as shown below. SWITCH ON LINE OFF LINE SW 1-4 OFF OFF SW 1-3 ON OFF SW 1-2 ON OFF SW 1-1 ON ON On line : Normal operating mode. The AP should be always in the “On line”, other than when you delete the AP data.
PN-AP01 (AP01) PN-AP01 (AP01) 1. Locations of Lamps, Switches, and Connectors MB SENSE RUN MB SW1 L3 L2 L1 L0 RS0 IP SW0 PN-AP01 (AP01) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green L3 Flashes at 120 IPM while this card is operating normally. Indication of the status of CTS signal on the RS-232C port. L2 L0-L3 FUNCTION Indication of the status of DCD signal on the RS-232C port.
PN-AP01 (AP01) (3) Switch Settings Switch Settings SWITCH NAME SENSE (Rotary SW) SWITCH NUMBER SETTING POSITION 4-F FUNCTION Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-AP01 (AP01) Switch Settings (Continued) SWITCH NAME SW0 (Dip SW) ON 1 2 3 4 SWITCH NUMBER SETTING POSITION 1 OFF Always set to OFF 2 OFF Always set to OFF 3 OFF Always set to OFF 4 OFF Always set to OFF FUNCTION CHECK The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.
PN-BRTA (BRI) PN-BRTA (BRI) 1. Locations of Lamps, Switches, and Connectors SENS RUN MB B1 B2 D ALM SW0 SW1 PN-BRTA (BRI) Card CHAPTER 4 Page 62 Revision 2.
PN-BRTA (BRI) (2) Lamp Indications Lamp Indications on the PN-BRTA (BRI) Card LAMP NAME COLOR RUN Green Flashes at 120 IPM while this card is operating normally. Green B1 channel status ON: Busy OFF: Idle Flash (60 IPM):Make Busy B2 Green B2 channel status ON: Busy OFF: Idle Flash (60 IPM):Make Busy D Green D channel status ON: Busy OFF: Idle ALM Red B1 FUNCTION Transmission line fault status ON: Line fault OFF: Normal operation ND-45504 (E) CHAPTER 4 Page 63 Revision 2.
PN-BRTA (BRI) (3) Switch Settings Switch Settings on the PN-BRTA (BRI) Card SWITCH NAME SWITCH NUMBER SENS (Rotary SW) 4-F 0 SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) as set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-BRTA (BRI) Note 3: Set SW0-2 and SW0-3 as follows. No. of BRI SW CONDITIONS When one BRI is provided. BRI 0 BRI 1 SW 0-2 SW 0-3 BRI 2 SW 0-2 SW 0-3 .... BRI 11 SW 0-2 SW 0-3 REMARKS SW 0-2 SW 0-3 ON ON The MP card will receive the clock signal from BRI 0 at its PLO 0 input. ON The MP card will receive the clock signal from BRI 0 at its PLO 0 input under normal conditions.
PN-2BRTC (BRI) PN-2BRTC (BRI) 1. Locations of Lamps, Switches, and connectors SENS RUN MB B21 B11 D1 ALM1 B20 B10 D0 ALM0 SW10 SW11 SW0 PN-2BRTC (BRI) Card CHAPTER 4 Page 65-1 Revision 2.
PN-2BRTC (BRI) 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green B21 Red B11 Red D1 Green ALM1 Red B20 Red B10 Red D0 Green ALM0 Red FUNCTION Flashes at 120 IPM while this card is operating normally. No.1 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D channel status ON: Busy OFF: Idle Transmission line fault status ON: Line fault OFF: Normal operation No.
PN-2BRTC (BRI) 3. Switch Settings Switch Settings SWITCH NAME SENS (Rotary SW) SWITCH NUMBER SETTING POSITION 4~F 0 Note 1 FUNCTION CHECK Set the switch to match the AP Number (04-15) as set by CM05. AP No. 04 05 06 07 08 09 10 11 12 13 14 15 SW No. 4 5 6 7 8 9 A B C D E F 0~3 Not used MB (Toggle SW) UP For make-busy ON DOWN For normal operation Note 2 SW0, SW10 (Dip SW) 1 2 ON ON For terminating the transmitting side of channels B1 and B2 with 100 ohms.
PN-2BRTC (BRI) Switch Settings (Continued) SWITCH NUMBER SWITCH NAME SETTING POSITION SW11 (Dip SW) FUNCTION CHECK ON For normal operation (BRI mode) OFF Not used ON Output clock signals according to the switch setting of SW11-3. OFF Do not output clock signals. ON Output clock signals to PLO 0 of MP. OFF Output clock signals to PLO 1 of MP.
PN-CC00 (ETHER) PN-CC00 (ETHER) 1. Locations of Lamps, Switches, and Connectors PN-CC00 PZ-M397 ETHER RUN RUN SW SW ERR S1 S2 S3 ERR S1 S2 S3 IP SW31 SW51 PN-CC00 (ETHER) Card CHAPTER 4 Page 66 Revision 2.
PN-CC00 (ETHER) 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green ERR Red S1 Green Lights when it is transmitting or receiving the data. S2 Green Lights when it can transmit or receive the data. S3 Green Lights when the power sets ON. Steadily lights while this card is operating normally. Flashes at 120 IPM when system error occurs. ND-45504 (E) Addendum-001 JULY, 1998 CHAPTER 4 Page 67 Revision 2.
PN-CC00 (ETHER) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SW (Rotary SW) SETTING POSITION 0 FUNCTION CHECK Always set to 0 Not used 1-F SW51 (Dip SW) ON 1 2 3 4 5 6 7 8 1 (D15) 2 (D14) 3 (D13) 4 (D12) 5 (D11) Note 6 (D10) 7 (D9) 8 (D8) 1 (D7) SW31 (Dip SW) ON 1 2 3 4 5 6 7 8 2 (D6) 3 (D5) Note 4 (D4) 5 (D3) 6 (D2) 7 (D1) 8 (D0) Note: ON ON ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON:0 OFF:1 MAC ADDRESS SWITCH SETTING 000
PN-CC01 (ETHER) PN-CC01 (ETHER) 1. Location of Lamps, Switches, and Connectors SW1 SW2 RUN MB LINK XMT RCV RVP ERR 10 BASE-T IP PN-CC01 (ETHER) Card ND-45504 (E) Addendum-001 JULY, 1998 CHAPTER 4 Page 68-1 Revision 2.
PN-CC01 (ETHER) 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green Flashes at 60 IPM while this card is operating normally. LINK Green Lights when link is established. XMT Green Lights when it is transmitting the data. RCV Green Lights when it is receiving the data. RVP Green Lights only when it is receiving the data with its own IP address. ERR CHAPTER 4 Page 68-2 Revision 2.
PN-CC01 (ETHER) 3.
This page is for your notes. CHAPTER 4 Page 68-4 Revision 2.
PN-CK00 (PLO) PN-CK00 (PLO) 1. Locations of Lamps, Switches, and Connectors SYNC PLO0 PLO1 ALM DRFT MB SW0 PN-CK00 (PLO) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION SYNC Green Lights while clock signals from this card are sent out and are not DRIFT status. PLO0 Green Lights while receiving clock signals from the network to the PLO0 input on this card. PLO1 Green Lights while receiving clock signals from the network to the PLO1 input on this card.
PN-CK00 (PLO) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER MB (Toggle SW) SETTING POSITION UP FUNCTION CHECK For make-busy ON DOWN For normal operation Note SW0 (Piano Key SW) Selection of PLO 0 (Phase Locked Oscillator) SWITCH NUMBER OFF FUNCTION 1 2 ON ON 2 MHz clock [For PN-30DTC/PN-30DTC-A/ PN-2BRTC] OFF ON 1.
PN-CK00 (PLO) Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card. Note 2: When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows. SW2-2: OFF SW2-3: ON Note 3: When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as follows.
PN-24DTA (DTI) PN-24DTA (DTI) 1. Locations of Lamps, Switches, and Connectors SENS RUN MB SW JPS CRC PCM FRM RMT AIS BL JPR1 JPR0 PN-24DTA (DTI) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Lights when detecting PCM signal loss. FRM Red Lights when detecting a Frame Alignment signal loss. RMT Red Lights when receiving a Frame Alignment signal loss alarm from a distant office.
PN-24DTA (DTI) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENS (Rotary SW) 4-F SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO. 4 5 6 7 8 9 A B C D E F Note 1 0-3 Not used For make-busy MB (Toggle SW) UP ON For normal operation DOWN Note 2 SW (Piano Key SW) ON Clock signal from a master office is sent to the PLO 0 input on the MP card.
PN-24DTA (DTI) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION Right Neutral grounding on the transmitting line is not provided. JPS (Jumper pin) Left JPR0 (Jumper pin) CHECK Neutral grounding on the transmitting line is provided. Neutral grounding on the receiving line is not provided. Up Neutral grounding on the receiving line is provided.
PN-24DTA-A (DTI) PN-24DTA-A (DTI) 1. Location of Lamps, Switches, and Connectors [When Card Issue No. is before 5A] [When Card Issue No. is after 5B] SENS SENS RUN RUN MB MB SW SW AISS AISS MAS JPR1 JPS CRC PCM FRM RMT AIS BL MAS JPR1 JPR0 JPS CRC PCM FRM AIS RMT BL JPR0 PN-24DTA-A (DTI) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Lights when detecting PCM signal loss.
PN-24DTA-A (DTI) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENS (Rotary SW) 4~F Note 1 SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 ~ 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO. 4 5 6 7 8 9 A B C D E F 0~3 Not used MB (Toggle SW) UP For make-busy ON DOWN For normal operation Note 2 ON Clock signal from a master office is sent to the PLO 0 input on the MP card.
PN-24DTA-A (DTI) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION Right Neutral grounding on the transmitting line is not provided. JPS (Jumper pin) Left Neutral grounding on the transmitting line is provided. Right Neutral grounding on the receiving line is provided. Left Neutral grounding on the receiving line is not provided.
PN-24DTA-A (DTI) Note 3: Set SW-1 and SW-2 as follows: No. of DTI SW CONDITIONS When one DTI is provided. When more than one DTI is provided. Note 4: DTI0 DTI1 DTI2 DTI3 DTI4 SW- SW- SW- SW- SW- SW- SW- SW- SW- SW1 2 1 2 1 2 1 2 1 2 REMARKS The MP card will receive the clock signal from DTI0 at its PLO0 input. ON OFF ON The MP card will receive the clock signal from DTI0 at its PLO0 input, under normal conditions.
PN-30DTC/30DTC-A (DTI) PN-30DTC/30DTC-A (DTI) 1. Locations of Lamps, Switches, and Connectors SENS RUN MB SW PCM FRM MFRM RMT MRMT AIS BL JPS JPR JP PN-30DTC/30DTC-A (DTI) Card ND-45504 (E) Addendum-001 JULY, 1998 CHAPTER 4 Page 78-1 Revision 2.
PN-30DTC/30DTC-A (DTI) 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green PCM Red Lights when detecting PCM signal loss. FRM Red Lights when detecting Frame Alignment signal loss. MFRM Red Lights when detecting Multi-Frame Alignment signal loss on time slot 16. RMT Red Lights when receiving an alarm because Frame Alignment signal loss has been detected at the distant office.
PN-30DTC/30DTC-A (DTI) 3. Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENS (Rotary SW) 4~F 0 Note 1 SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04-15) as set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-30DTC/30DTC-A (DTI) Switch Settings SWITCH NAME JPS (Jumper pin) SWITCH NUMBER SETTING POSITION UP DOWN JPR (Jumper pin) JP (Jumper pin) UP FUNCTION CHECK Balanced transmission (For twisted-pair cable) TA is grounded on the transmission line (For coaxial cable) Note 4 Balanced transmission (For twisted-pair cable) DOWN RA is grounded on the transmission line (For coaxial cable) RIGHT Line impedance: 75 ohms Note 4 (For coaxial cable) LEFT Line impedance: 120 ohms (For twisted-pair cabl
PN-30DTC/30DTC-A (DTI) Note 3: Set SW-1 and SW-2 as follows. No. of DTI CONDITIONS DTI 0 DTI 1 DTI 2 DTI 3 REMARKS SW SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 When one DTI is provided. When more than one DTI is provided. ON ON OFF The MP card will receive the clock signal from DTI 0 at its PLO 0 input. OFF The MP card will receive the clock signal from DTI 0 at its PLO 0 input, under normal conditions.
This page is for your notes. CHAPTER 4 Page 78-6 Revision 2.
PN-ME00 (EXTMEM) PN-ME00 (EXTMEM) 1. Locations of Lamps, Switches, and Connectors JP0 SENS RUN JP2 MB WP BAT CN0 PN-ME00 (EXTMEM) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green WP Red FUNCTION Flashes at 120 IPM while this circuit card is operating normally. Lights when the RAM is being accessed. Lights indicating the status (Write Protect Switch status and the battery voltage status) of the SRAM card on this circuit card.
PN-ME00 (EXTMEM) How to Handle the SRAM Card ■ Mounting the SRAM Card ① ② ③ ④ ⑤ Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card. Mount the battery on the battery case, then insert the battery case into the SRAM card. Slide the lock switch upward (Lock). Mount the SRAM card in the PN-ME00 card. Slide the write protect switch downward (Active).
PN-ME00 (EXTMEM) ■ Removing the SRAM Card ➀ Push the card slot bar of the PN-ME00 card. ➁ Remove the SRAM card. PN-ME00 PUSH SRAM Removing the SRAM Card ■ Replacing the SRAM Battery CAUTION To prevent loss of memory on an active system, the battery must be replaced when the SRAM card is installed on the PN-ME00, and the PN-ME00 is installed in the system. Also, power to the system must be “ON”. ➀ Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.
PN-ME00 (EXTMEM) PN-ME00 REMOVE THE BATTERY CASE LITHIUM BATTERY: BR2325 OR CR2325 Replacing the SRAM Battery CHAPTER 4 Page 82 Revision 2.
PN-ME00 (EXTMEM) (3) Switch Settings Switch Settings SWITCH NAME SENSE (Rotary SW) SWITCH NUMBER SETTING POSITION 4-F Note 1 FUNCTION Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-4RSTB (MFR) PN-4RSTB (MFR) 1. Locations of Lamps, Switches and Connectors SENS RUN MB SW OPE3 OPE2 OPE1 OPE0 PN-4RSTB (MFR) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green OPE Red CHAPTER 4 Page 84 Revision 2.0 FUNCTION Flashes at 120 IPM while the circuit card is operating normally. • Lights when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned.
PN-4RSTB (MFR) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER 4-F SENS (Rotary SW) SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO. 4 5 6 7 8 9 A B C D E F Note 1 0-3 MB (Toggle SW) Not used UP For make-busy For normal operation ON DOWN Note 2 SW (Piano Key SW) ON For make-busy No. 0 circuit 1 OFF ON For normal operation For make-busy No.
PN-4RSTC (CIR) PN-4RSTC (CIR) 1. Locations of Lamps, Switches and Connectors SENSE RUN MB SW1 BL3 BL2 BL1 BL0 JP0 PN-4RSTC (CIR) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green BL0-3 Red CHAPTER 4 Page 86 Revision 2.0 FUNCTION Flashes at 120 IPM while the circuit card is operating normally. Lights when receiving a CALLER ID (CLASS SM) signal.
PN-4RSTC (CIR) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENSE (Rotary SW) 4-F SETTING POSITION FUNCTION Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO. 4 5 6 7 8 9 A B C D E F 0-3 Note 1 CHECK Not used MB(Toggle SW) UP For make-busy ON DOWN For normal operation Note 2 SW1 (Piano Key SW) ON 1 OFF ON OFF 2 4 3 OFF ON 3 2 1 ON OFF ON 4 For make-busy No.
PN-SC00 (CCH) PN-SC00 (CCH) 1. Locations of Lamps, Switches and Connectors SW1 SENS RUN MB SW0 LC LPB RS PN-SC00 (CCH) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Lights when communications are normally ongoing with the common signalling channel data links connected. LPB Green Lights when a loop-back test is in progress. CHAPTER 4 Page 88 Revision 2.
PN-SC00 (CCH) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENS (Rotary SW) Note 1 4-F SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-SC00 (CCH) Switch Settings (Continued) SWITCH NAME SWITCH NUMBER SETTING POSITION ON 1 OFF ON 2 FUNCTION • Common channel signalling data transmission speed (For Digital Interface) TRANSMISSION SPEED SW 1-1 SW 1-2 SW 1-3 SW 1-4 SW 1-5 48Kbps ¨ 48Kbps ¦ 56Kbps 64Kbps ON ON ON ON ON ON ON ON OFF ON OFF ON OFF OFF ON ON ON ON ON ON OFF ON 3 SW1(Dip SW) OFF ON ON 12345 678 4 OFF CHECK • Common channel signalling data transmission speed (For Analog Interface) Set switches (SW1-1 - SW1-5
PN-SC01 (DCH) PN-SC01 (DCH) 1. Locations of Lamps, Switches and Connectors SW1 SENS RUN MB SW0 LC LPB PN-SC01 (DCH) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Lights when communications are normally ongoing with the D channel data links connected. LPB Green Not used. ND-45504 (E) CHAPTER 4 Page 91 Revision 2.
PN-SC01 (DCH) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENS (Rotary SW) 4-F SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-SC01 (DCH) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1: Set the groove on the switch knob onto the intended switch position. Note 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. ND-45504 (E) CHAPTER 4 Page 93 Revision 2.
PN-SC02 (ICH) PN-SC02 (ICH) 1. Locations of Lamps, Switches, and Connectors SENS RUN MB DOPE1 DOPE0 SW0 PN-SC02 (ICH) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR RUN Green Flashes at 120 IPM while this card is operating normally. DOPE0 Green ON: No. 0 circuit D channel link is connected. OFF: No. 0 circuit D channel link is not connected. DOPE1 Green ON: No. 1 circuit D channel link is connected. OFF: No. 1 circuit D channel link is not connected.
PN-SC02 (ICH) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SENS (Rotary SW) 4-F SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 - 15) to be set by CM05. AP NO. 04 05 06 07 08 09 10 11 12 13 14 15 SW NO.
PN-SC03 (ICH) PN-SC03 (ICH) 1. Locations of Lamps, Switches, and Connectors SENSE RUN MB DOPE7 DOPE6 DOPE5 DOPE4 DOPE3 DOPE2 DOPE1 DOPE0 PN-SC03 (ICH) Card 2. Lamp Indications Lamp Indications on ICH Card LAMP NAME COLOR RUN Green Flashes at 120 IPM while the card is operating normally. DOPE7 Green Lights when No.7 circuit D channel link is connected. DOPE6 Green Lights when No.6 circuit D channel link is connected. DOPE5 Green Lights when No.5 circuit D channel link is connected.
PN-SC03 (ICH) (3) Switch Settings Switch Settings on ICH Card SWITCH NAME SWITCH NUMBER SENSE (Rotary SW) 4~F SETTING POSITION FUNCTION CHECK Set the switch to match the AP Number (04 ~ 15) to be set by CM05. AP No. 04 05 06 07 08 09 10 11 12 13 14 15 SW No.
PN-SC03 (CSH) PN-SC03 (CSH) 1. Locations of Lamps, Switches, and Connectors SENSE RUN MB DOPE7 DOPE6 DOPE5 DOPE4 DOPE3 DOPE2 DOPE1 DOPE0 PN-SC03 (CSH) Card CHAPTER 4 Page 98 Revision 2.
PN-SC03 (CSH) (2) Lamp Indications Lamp Indications on CSH Card LAMP NAME COLOR RUN Green Flashes at 120 IPM while the card is operating normally. DOPE7 Green Lights when No.7 circuit D channel link is connected. DOPE6 Green Lights when No.6 circuit D channel link is connected. DOPE5 Green Lights when No.5 circuit D channel link is connected. DOPE4 Green Lights when No.4 circuit D channel link is connected. DOPE3 Green Lights when No.3 circuit D channel link is connected.
4. LAMP INDICATIONS AND SWITCH SETTINGS OF LINE/TRUNK CIRCUIT CARDS Table 4-3 below shows the line/trunk circuit cards to be explained in this section.
PN-2AMPA (AMP) PN-2AMPA (AMP) 1. Locations of Lamps, Switches and Connectors BL1 BL0 PN-2AMPA (AMP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 101 Revision 2.
PN-AUCA (AUC) PN-AUCA (AUC) 1. Locations of Lamps, Switches and Connectors BL1 BL0 CN1 PN-AUCA (AUC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. CHAPTER 4 Page 102 Revision 2.
PN-CFTA (CFT) PN-CFTA (CFT) 1. Locations of Lamps, Switches and Connectors BL1 PN-CFTA (CFT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 Red • Remains lit when the card is in use. • Flashes (60 IPM) When the circuit on the card is in the make-busy state on the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 103 Revision 2.
PN-4COTB (COT) PN-4COTB (COT) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 CN1 PN-4COTB (COT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. CHAPTER 4 Page 104 Revision 2.
PN-4COTG (COT) PN-4COTG (COT) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 CN1 PN-4COTG (COT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 105 Revision 2.
PN-2DATA (DAT) PN-2DATA (DAT) 1. Locations of Lamps, Switches and Connectors BL1 BL0 SW PN-2DATA (DAT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. CHAPTER 4 Page 106 Revision 2.
PN-2DATA (DAT) (3) Switch Settings Switch Settings SWITCH NAME SW (Piano Key SW) SWITCH NUMBER SETTING POSITION ON CHECK Data write into the No.1 circuit is disabled. SW-0 OFF ON SW1 ON SW0 FUNCTION Data write into the No.1 circuit is enabled. Data write into the No.1 circuit is disabled. SW-1 OFF OFF Data write into the No.1 circuit is enabled. The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch.
PN-DK00 (DK) PN-DK00 (DK) 1. Locations of Lamps, Switches and Connectors PN-DK00 (DK) Card 2. Lamp Indications This card has no indicator lamps. 3. Switch Settings This card has no switches. CHAPTER 4 Page 108 Revision 2.
PN-4DITB (DIT) PN-4DITB (DIT) 1. Locations of Lamps, Switches, and Connectors BL3 BL2 BL1 BL0 PN-4DITB (DIT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION Red • Light when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. BL0 ~ 3 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 109 Revision 2.
PN-2DLCB (DLC) PN-2DLCB (DLC) 1. Locations of Lamps, Switches and Connectors BL1 BL0 CN0 PN-2DLCB (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 , 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. CHAPTER 4 Page 110 Revision 2.
PN-2DLCC (DLC) PN-2DLCC (DLC) 1. Locations of Lamps, Switches and Connectors BL1 BL0 PN-2DLCC (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 , 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 111 Revision 2.
PN-2DLCN (DLC) PN-2DLCN (DLC) 1. Locations of Lamps, Switches and Connectors BL1 BL0 CN0 PN-2DLCN (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. CHAPTER 4 Page 112 Revision 2.
PN-4DLCA (DLC) PN-4DLCA (DLC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 PN-4DLCA (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 113 Revision 2.
PN-4DLCD (DLC) PN-4DLCD (DLC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 PN-4DLCD (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0-3 Red • Remains lit when the corresponding circuit is in use • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned 3. Switch Settings This card has no switches. CHAPTER 4 Page 114 Revision 2.
PN-4DLCF (DLC) PN-4DLCF (DLC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 CN1 PN-4DLCF (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 115 Revision 2.
PN-4DLCM (DLC) PN-4DLCM (DLC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 PN-4DLCM (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0-3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. CHAPTER 4 Page 116 Revision 2.
PN-4DLCQ (DLC) PN-4DLCQ (DLC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 PN-4DLCQ (DLC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0-3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 117 Revision 2.
PN-2DPCB (DPC) PN-2DPCB (DPC) 1. Location of Lamps, Switches and Connectors RSC1 SDT1 RDR1 CDI1 BL1 LB11 LB12 RSC0 SDT0 RDR0 CDI0 BL0 LB01 LB02 SW1 SW0 XCN1 XCN0 RS1 RS0 PN-2DPCB (DPC) Card CHAPTER 4 Page 118 Revision 2.
PN-2DPCB (DPC) (2) Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 Red ON: Ready for digital data transmission or the circuit is busy. OFF: Fixed path is not connected. Flash (60IPM): Make-busy state or the system data for this card is not assigned. Flash (120IPM): Fixed path is connected. LB01 Red ON: Loop Back 1 is set. OFF: Normally operating. LB02 Red ON: Loop Back 2 is set. OFF: Normally operating. No. 0 Circuit RSC0 Green ON: RTS/C signal ON. OFF: RTS/C signal OFF.
PN-2DPCB (DPC) (3) Switch Settings Switch Settings SWITCH NAME SW1 (Piano Key SW) SWITCH NUMBER SETTING POSITION ON CHECK Loop Back 1 ON 1 OFF ON OFF FUNCTION No. 0 Circuit Loop Back 1 OFF Loop Back 2 ON 2 4 3 2 OFF Loop Back 2 OFF ON Loop Back 1 ON 3 OFF 1 ON ON No.
PN-2ILCA (ILC) PN-2ILCA (ILC) 1. Locations of Lamps, Switches, and Connectors ACT1 PAL1 LPB1 B21 B11 ACT0 PAL0 LPB0 B20 B10 SW1 SW0 PN-2ILCA (ILC) Card ND-45504 (E) CHAPTER 4 Page 121 Revision 2.
PN-2ILCA (ILC) (2) Lamp Indications Lamp Indications LAMP NAME COLOR ACT1 Green PAL1 Red LPB1 Red B21 Green ON: B2 channel is in use. OFF: B2 channel is idle. B11 Green ON: B1 channel is in use. OFF: B1 channel is idle. ACT0 Green ON: Normally operating. OFF: Not operating. PAL0 Red LPB0 Red B20 Green ON: B2 channel is in use. OFF: B2 channel is idle. B10 Green ON: B1 channel is in use. OFF: B1 channel is idle. CHAPTER 4 Page 122 Revision 2.0 FUNCTION ON: Normally operating.
PN-2ILCA (ILC) (3) Switch Settings Switch Settings SWITCH NAME SW1 (Piano Key SW) OFF SWITCH NUMBER SETTING POSITION 1 OFF 2 OFF 3 OFF 4 OFF FUNCTION CHECK Always set to OFF Always set to OFF 4 3 2 1 Always set to OFF Always set to OFF ON SW0 (Piano Key SW) 1 ON OFF No. 0 Circuit (Receiving) Terminating register is provided. No. 0 Circuit (Sending) Terminating register is provided. No. 1 Circuit (Receiving) Terminating register is provided. No.
PN-4LCD/4LCD-A (LC) PN-4LCD/4LCD-A (LC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 PN-4LCD/4LCD-A (LC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0-3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. CHAPTER 4 Page 124 Revision 2.
PN-4LCJ (LC) PN-4LCJ (LC) 1. Locations of Lamps, Switches and Connectors BL3 BL2 BL1 BL0 PN-4LCJ (LC) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 3 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 125 Revision 2.
PN-M03 (M03) PN-M03 (M03) 1. Locations of Lamps, Switches and Connectors OPRS OPER SW0 OPSD OPE RS SD RD CD ER DR CS SELX21 X21 SELCN0 CN0 JP1B V35 JP1A PN-M03 (M03) Card CHAPTER 4 Page 126 Revision 2.
PN-M03 (M03) (2) Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION OPE Green ON: This card is normally connected to the PN-2DPCB. OFF: This card is abnormally connected to the PN-2DPCB. RS Green ON: RTS signal is ON. OFF: RTS signal is OFF. SD Green ON: TXD signal is “0” (Space condition). OFF: TXD signal is “1” (Mark condition). RD Green ON: RXD signal is “0” (Space condition). OFF: RXD signal is “1” (Mark condition). CD Green ON: DCD signal is ON. OFF: DCD signal is OFF.
PN-M03 (M03) (3) Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION 1 OFF SW0 (Dip SW) FUNCTION CHECK Always set to OFF. Not used. 2 2 1 OFF ON JP1A (Jumper pin) TXC(2) signal is sent out. Right TXC(2) signal is inputted. Left Note JP1B (Jumper pin) TXC(2) signal is sent out. Right TXC(2) signal is inputted. Left Note OPSD (Jumper pin) Set the function of extending distance for TXD signal.
PN-2ODTA (ODT) PN-2ODTA (ODT) 1. Locations of Lamps, Switches and Connectors BL1 BL0 CN1 PN-2ODTA (ODT) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION BL0, 1 Red • Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for this card is not assigned. 3. Switch Settings This card has no switches. ND-45504 (E) CHAPTER 4 Page 129 Revision 2.
PN-8RSTA (PBR) PN-8RSTA (PBR) 1. Locations of Lamps, Switches and Connectors PN-8RSTA (PBR) Card 2. Lamp Indications This card has no indicator lamps. 3. Switch Settings This card has no switches. CHAPTER 4 Page 130 Revision 2.
PN-TNTA (TNT) PN-TNTA (TNT) 1. Location of Lamps, Switches and Connectors SW JACK1 JACK0 PN-TNTA (TNT) Card 2. Lamp Indications This card has no lamps. ND-45504 (E) CHAPTER 4 Page 131 Revision 2.
PN-TNTA (TNT) 3. Switch Settings Switch Settings SWITCH NAME SWITCH NUMBER SW (Piano Key SW) SETTING POSITION FUNCTION Volume adjustment for No. 0 circuit SWITCH NUMBER OFF 1, 2 4 CHECK 3 2 1 2 OFF ON OFF ON OFF OFF ON ON VOLUME –10 dB –7 dB –4 dB –1 dB 1 ON Volume adjustment for No. 1 circuit SWITCH NUMBER 3, 4 CHAPTER 4 Page 132 Revision 2.
PN-2CSIA (CSI) PN-2CSIA (CSI) 1. Locations of Lamps, Swtiches, and Connectors. OPE LB B13 B12 B11 B10 B03 B02 B01 B00 DL1 DL0 PN-2CSIA (CSI) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR OPE Green LB Red Lights when a loop-back is in progress. B13 Red Not used (Flash [60IPM]) Red B channel status ON : B2 channel of the No. 1 circuit is in use. OFF : B2 channel of the No. 1 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 1 circuit. ZT is in make-busy status.
PN-2CSIA (CSI) Lamp Indications LAMP NAME FUNCTION B10 Red B channel status ON : B0 channel of the No. 1 circuit is in use. OFF : B0 channel of the No. 1 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 1 circuit. ZT is in make-busy status. B03 Red Not used (Flash[60 IMP]) Red B channel status ON : B2 channel of the No. 0 circuit is in use. OFF : B2 channel of the No. 0 circuit is in idle. Flash (60 IPM) : ZT is not connected to the No. 0 circuit. ZT is in make-busy status.