user manual

Page 3-32 NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.7 Communication Status Reading Command
RMAC Read Manufacturer Code 7-1
Description: Acquires manufacturer code of a remote site.
Command Format: RMAC
Response: Normal Response: p1 p2 p3 p4 p5 OK
p1: 00-FF : Manufacturer code 49: NEC
Else: other vendor
p2: 00-FF : Division code 00: NEC
Else: other division of NEC
p3: 00-FF : Unit code 01: TC5000EX7/10
02: MMVC
03: VL128/384
10: MCU5000A
Else: Reserved
p4: 00-FF : Own Capability code
D0: Kanji Display Capability 0: Off (option)
1: On (option)
D1: Composite Screen Display Capability 0: Off
1: On
D2: H281 Camera Control Capability 0: Off (option)
1: On (option)
p5: 00-FF : Reserved
Error Response: ERR01
ERR07
ERR42
ERR46
ERR47
ERR85
ERR87
D7 D6
D5
D4
D3
D2
D1
D0