NDA-24233 Issue 2 Page 3-37
VisuaLink 128/384 Engineering Guide Console Command List
CALM Read Alarm Status (2 of 2) 8-1
Response
p4: Bonding alarm
D0: Bonding frame loss 0: normal 1: abnormal
D1: Bonding speed negotiation fail 0: normal 1: abnormal
D2: Network type negotiation fail 0: normal 1: abnormal
D3: Dialing number negotiation fail 0: normal 1: abnormal
D4: Additional channel connection fail 0: normal 1: abnormal
D5-7:Unused 0: fixed
p5: TEST status
D0-3: Unused 0: fixed
D4-5: Local Loopback 00: Off
01: Video
10: Audio
11: LINE
D6-7: Unused 0: fixed
p6: TEST status 2
D0-1: Video mute 0: OFF 1: ON
D2-3: Unused 0: Fixed
D4: Audio mute 0: OFF 1: ON
D5: Line 1 loopback 0: OFF 1: ON
D6: Line 2 loopback 0: OFF 1: ON
D7: Line 3 loopback 0: OFF 1: ON
Error Response: ERR01
ERR07
ERR87
D7 D6
D5
D4
D3
D2
D1
D0
D7 D6
D5
D4
D3
D2
D1
D0
D7 D6
D5
D4
D3
D2
D1
D0