user manual

ND-20292
CHAPTER 3
APRIL, 1990
MEMORY BLOCK lE2 - TERMINAL ADD-PORT (EQUIPMENT TYPE
ASSIGNMENT )
4.
5.
6.
7.
OPERATION -I AND -w DISPLAY
Go off line.
OF F - LINE (X-XX)
PROGRAM
MODE
Depress Fl, then FlO.
,TERMINAL ASSIGN
Depress F12.
Enter module number (1 to 4), to select a specific
CCU. Example: 1. (Selects the ESE-32B-1 CCU).
Enter slot number
(1
to 81, to select a specific
interface slot. Example: 3. (Selects the 3rd card
slot from the right side of the selected CCU).
Enter channel number (1 to 41, to select a specific
circuit of an interface card.
Example: 4. (Selects the 4th circuit on the selected
card slot, in step 5).
Depress the line key associated with thqdey&E
type to be assigned to the port. (See Note 1).
8. Depress ENTER key. (See Notes 3,4, & 5).
9.
10.
Depress TEL # key and repeat steps 4 to 8 for all
additional port assignments. (See Note 2).
Depress the SPKR key to go back on line.
TERM.ADD PORT
MOD?
SLOT* CH*
TERM.ADD
PORT
-MOD1 SLOT? CH*
TE RM.ADD
PORT
MOD1
S L OT 3 CH?
‘>
TERM.ADD PORT
MOD1
SLOT3
CH4
TERM.ADD
PORT
MOD1
SLOT3 CH4
TERM.ADD PORT
MOD1
SLOT4 CHl
TERM.ADD
PORT
MOD?
SLOT* CH*
300 - 52