MEMORY BLOCK 3D3 - SLOT INITIALIZATION
OPERATION - AND 8-w DISPLAY
1. Go off line.
OFF -LINE (X-XX)
PROGRAM MODE
2. Depress F3, then F9.
SYS.
lNlTlALlZE
3. Depress F13.
4. Dial module number (l-4) of the slot to be
initialized.
Example: Module 1. (See Note 1).
5. Dial slot number (l-8) to be initialized.
Example: Slot 5. (See Note 1).
6. Depress ENTER key.
(1) When initialized
(2) When not initialized
SLOT INITIALIZE
MODULE? SLOT*
SLOT INITIALIZE
MODULE1 SLOT?
SLOT INITIALIZE
MODULE1 SLOT5
SLOT INITIALIZE
MODULE?
SLOT*
SLOT INITIALIZE
NOT INITIALIZED
7. Depress SPKR key to go back on line.