CHAPTER 3
APRIL, 1990
4. Depressing the ENTER key causes the dis
to increment to the next channel, or the F
lay
lrst
channel of the next slot with a COI-E ETU.
KEY FUNCTION (OFF LINE)
SPKR - ON/OFF Line
TEL # - Selects CO1 port number
F/W - Increments channel number
CLEAR -
ENTER - Enters each assignment
B/W - Decrements channel number
GUIDE TO FEATURE PROGRAMMING
MEMORY BLOCK THAT MEMORY BLOCK THAT MAY
/I
All CPU levels (See L4 in Note 2).
NOTES:
1. It is recommended that 4B6 be programmed prior to
4B1, since 4B6 programming overrides all 4Bl
programming already done for all the trunks in the
group.
2. During step 6, the status of Ll to L12 LEDs indicate
the current parameters set to the CO1 channel
selected. See figure below.
Ll = 10 or 20 PPS for rotary dialing
(Default: 10 PPS)
L2 = Rotary or DTMF dialing (Default: DTMF)
L3 = CO or PBX line interface (Default: CO)
L4= Disconnect Signal from CO (YES/NO)
(Default: NO) (CPU-EBB or higher)
A disconnect signal must be sent from CO for
Trunk to Trunk transfer to operate.
L5 to L8 = DTMF digit duration
(50 mS. x M) + 60 mS.
(Default: 110 mS.)
L9 to L12 = CO Hookflash time
(100 mS. x M) + 300 mS.
(Default: 1500 mS.)
To adjust CO Hookflash on a Ground Start
Trunk, the Trunk must be assigned as PBX
(LK3, ON). If the Trunk is assigned as CO
(LK3, OFF) the Hookflash will be 1,500 mS.
3. See Section 350 for definitions and additional
information.
LED
LED OFF means upper parameter
\
Ll L2 L3 L4 L5 1 L6
I
L7 I L8
DTMF DURATION
23 22
2’ 2O
LED
L9 I LlO I Lll I L12 L13
L14
L15 L16
CO HOOKFLASH TIME
22 2’ 2O
~.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.~.~.-.~.~.~.~.~.~.-.~.~.~.~.~.-.~.~.~.~.-.~.~.~.~.~.~.-.-.~.-.~.-.~.~.~
GENERAL INFORMATION - COI-I INITIALIZED VALUES
[This area of the memory block is used to set the parameters to COI-E ports on a per port (channel) basis.
i
i
300 - 199