user manual

JOB SPECIFICATION INSTRUCTIONS
FOR
MEMORY BLOCKS 4B-1 AND -2
CO1 INITIALIZED VALUES
ITEM
DESCRIPTION ENTRY
TIMING OF CO / PBX HOOK FLASH FROM THE
RECALL KEY OF A MULTILINE TERMINAL TO THE
co
DURATION OF A DIALED DTMF DIGIT
DISCONNECT SIGNAL FROM CO
SELECT WHETHER DIAL TONE IS CO DIAL
TONE OR PBX DIAL TONE
SELECT EITHER
PUSHBUTTON
ORROTARY
DIALING, DEPENDING ON CO / PBX CAPABILITY
AND CUSTOMER REQUIREMENTS
SELECT THE PULSE RATE USED FOR ROTARY
DIALING, DEPENDING UPON CO TYPE
THE TIME DURATION BETWEEN EACH DIGIT
DIALED
DURATION OF SPEED DIAL PAUSES
RELEASE TIME OF A CO LINE
DETECTION TIMING OF THE CO DISCONNECT
SIGNAL
300 - 1700 (100 mS. increments)
60 - 760 (50 mS. increments)
YES
OR NO
CO ORPBX
DTMF
OR
DP
10OR20
40 - 180 (10 mS. increments)
0 - 7000 (500 mS. increments)
0 - 1400 (100 mS. increments)
0 - 700 (50 mS. increments)