N. Using the separately ordered CCU base panel;
mount it to the wall just above the second ESE-
32E-1 CCU, ensuring that minimum space is
between the base panel and the second CCU.
Install the wall mounting metal brackets as shown in
Figure 200-11, using the eight locally provided
fasteners.
Upper Wall Mount
Bracket
CCU Base
Panel
Lower Wall Mount
Bracket
Figure 200-11 Wall Mount2
f
Bracket and CCU Base
Mount the base panel onto the lower bracket using the
two screws provided with the bracket.
Using the open slots provided on the back panel of the
CCU, mount the CCU to the knobs of the upper bracket
and onto the base panel.
Ensure the upper bracket
knobs are fully seated within the open slots of the
CCU. Tighten the screws from above the CCU to
securely attach the CCU to the upper bracket knobs,
install the two screws shown in Figure 200-12.
0. Install the top panel onto the top CCU and secure
with the screws removed in step C.
NOTE:
All removed front panels should be
reinstalled by securing with the screws
removed in step
B,
after the required
ETU’s are installed and the system is
tested. (Refer to Figure 200-14).
240.2 FLOOR MOUNTING THE CCU
NOTE: U L regulations require the fourth CCU
to always be mounted to the wall and is
to be attached to the other three CCUs.
Mounting of the fourth CCU should be
considered at the beginning to ensure
proper wall spacing for the stack’s
location.
Figure 200-12 Wall Mounting ESE-32B-1 CCU
The CCUs are designed to be wall mounted. When
necessary, floor mounting can be accomplished by
stacking the CCUs.
A.
B.
C.
D.
E.
F.
G.
H.
Place the ESE-32B-1 CCU by a wall in its
permanent and safe floor location.
Unscrew the two screws located on the lower
portion of the front panel, then remove the front
panel by sliding it to the left. Place the panel and
screws aside for later reinstallation.
Unscrew the two screws located on the top front of
the CCU, then remove the top panel. Place the‘
panel and screws aside for later reinstallation.
When the first ESE-32E-1 CCU is to be installed,
repeat step
B. Remove
the two screws located on
the top front of the CCU, then, mount the CCU
onto the ESE-32B-1 CCU.
Ensure that the hooks provided on the top rear of
the ESE-32B-1 CCU are fully seated in the open
slots on the bottom rear of the ESE-32E-1 CCU.
Secure them both by using the two screws
removed in step
D.
When the second ESE-32E-1 CCU is installed, it
should be attached in the same manner as the
first ESE-32E-1 CCU.
When the third ESE-32E-1 CCU is installed, it
should be attached in the same manner as the
second ESE-32E-1 CCU.
Using the guide lines for wall mounting, mount
the bracket for the third ESE-32E-1 ETU to the
wall, ensuring that the CCU stack is not leaning
in any direction.
200 - 20