user manual

--
ND-20292
ZIAPTER4
APRIL, 1990
SAMPLE LED INDICATIONS SAMPLE LCD INDICATIONS
430.2 CO Trunk Selection and Test
a. CO Trunk Selection and Test:
0
0
Depress Primary Extension line key.
Lift handset or depress SPKR key to
receive dial tone.
l
Dial Selection Access Code: (Default 67).
0
Dial Trunk Number (01-40) to be selected
(Example 03).
If the selected CO Trunk was idle and in
good working order when selected, dial
tone will be heard. Digits dialed will
appear in the LCD.
OR
0
lf the CO trunk selected was busy, Busy
Tone will be heard.
OR
0
If the CO Trunk number selected is not
installed, Reorder or busied out tone will
be heard.
0
Restore handset or depress SPKR key to
end testing. Repeat the above steps to
test each CO Trunk circuit as required.
NOTE: MFR circuits can also be tested, but this
must be performed from a Single Line
Telephone. Refer to Section 440.3 for
this procedure.
I
EXT green LED lit.
~1x1~1 1~11 1~1~1 I I [ I I I I
1101 :I4151
IoIcITI
12181
IFIRII
piiiG%J
red LED will light if the
selected trunk appears on the Attendant
Multiline Terminal or CO Add-On Module.
I I I
67
‘1 0
:I451 IOCT 28 FR I
I I
03
lo:)451 IOCT 28 FR J
I I
1 1121314 5161718 9
ilo :I4 51
10~1~1 12 8.1 IFIR I
ClOl’ 131 1 1 1 1 1 1 1 IBkJlStY.
1101 :I4151
IoIcJTI lalsl 1~1~11
co1 3 NOT I N S T AIL/L
101: 4 5 OCT 28 FIRI I
co 3 BUSYOUT
10145 OCT 28 FIR I
I I
10 : 415 OCT 28 FIR I
400 - 117