ET1 NUMBER: MK-001
DATE: FEBRUARY, 1987
PLANTRONICS JS-180 JACKSET CONNECTION
1.
DESCRIPTION
This Engineering Technical Information (ETI) Bulletin describes the steps necessary to install an ADA-E
(Ancillary Device Adapter) unit into an ETE-GD-1, ETE-16D-1, ETE-16K-1, or ETE-6-1 Multiline
Terminal, to provide for connection and operation of a Plantronics Jackset (Model JS-180).
2.
PARTS REQUIRED
2.1
2.2
2.3
2.4
ADA-E Unit Adapter Kit (Stock # 700340)
JS-180 Jackset
Compatible Headset
Electra Mark II Multiline Terminal
3.
OPERATION
3.1
.
3.2
3.3
By moving the Jackset Rocker Switch to the ON position, the Electra Mark II Multiline Terminal
will go into the OFF-HOOK condition. The operator can now talk over the headset, after depressing a
CO or extension line key on the Multiline Terminal.
The call can be terminated by moving the Rocker Switch to the OFF position.
The Multiline Terminal is seen as OFF-HOOK when the Jackset is turned on, therefore, it may be
desirable to program the Multiline Terminal for off-hook ringing.
4.
PROCEDURE
4.1 Turn the Multiline Terminal upside down (face down) and locate the access panel on the bottom of the
Multiline Terminal, refer to Figure 1.
4.2 Disconnect the modular line cord from under the telephone and from the RJ-llC/W jack.
4.3 Disconnect the modular handset cord from the lower housing.
4.4 Slide the directory out of the way (Not required for ETE-6-1 Multiline Terminal).
1 of 5