user manual

ET1 NUMBER: MK-002
DATE: MARCH, 1987
5.14 Install the ADA-E unit and secure it to the terminal housing with the screw provided, as shown in
Figure 2.
5.15 Two access panels are provided with the ADA kit, the narrower panel is used with the ETE-6-1
Multiline Terminal, the wider panel for all other Terminals.
Remove the plastic tongue on the
underside of the access panel being installed (using a pair of pliers) to provide clearance for cables in
the cable exit groove.
5.16 Place the RJ-35X cable into the cable exit groove (Figure 2) making certain that all wires are inside
the terminal housing. Install the proper access panel.
5.17 Reinstall the modular handset and modular line cords.
5.18 If slid out of the way in step 5.4, slide the directory back into place.
5.19 Plug the modular line cord of the Autodialer into the RJ-35X receptacle.
5.20 Plug in the Autodialer AC Adapter, first into the Autodialer and then into the nearest AC outlet.
5.21 Test both the Autodialer and the Multiline Terminal for proper operation.
3of6