The Genie Voice Mail System provides two ports (AIUs) for Voice Mail Access. These ports
connect to two (of the four available) VMI-E extension positions. These VMI-E extensions should
be cross-connected from the appropriate
J
block on the MDF and connected to an RI1 1C connector
to facilitate connection to the Genie using modular line cords (See Figure 11.
66
BLOCK
MDF
TO GENIE MODULAR
CONNECTORS
PORT 1 AND PORT 2
\
GENIE
PORT 2
0
STATUS
PORT 1
. STATUS
0 GIAGNOSTIC HALT
Figure 1. Genie Connection Block Diagram
4.2 Electra Mark11 System Programming
4.2.1
If the VMI-E ETU is being added to an existing system in an interface slot previously occupied by
a different type of ETU, it is necessary to assign the interface slot to be used for the VMI-E ETU in
Memory Block 4Cl. (Refer to Chapter 3 of the Installation/Service Manual).
4.2.2
The two voice mail extensions connected to the Genie System can be programmed in the Voice
Mail Hunt Group in Memory Block 2C4. (Refer to Chapter 3 of the Installation/Service Manual).
4.3 Installing/Initializing Genie
NOTE:
Ensure both the Genie and the computer terminal power switches are turned off.
4.3.1
Configure the serial computer terminal to be used with the Genie as follows:
l
8-bit word length
0 no parity
(ignore parity
on some terminals)
o 1 stop bit
l
auto-line feed off
l
full duplex
a 1200 baud