user manual

From one end of the station cable provided (step 3.4) remove approximately 4 inches of outer insulation
and strip off $ inch of the inner insulation from each of the four wires. To each conductor fasten one of
the spade lugs locally provided, either by soldering or crimping.
To remove the access panel, perform
only
the step that applies, either 4.6.1 or 4.6.2 (Refer to Figure 1).
4.6.1 ETE-GD-1, ETE-IGD-1, or ETE-16K-1 Multiline Terminal; Insert a flat scrcwdriver.bladc into
notched opening (shown as A) and apply light upward pressure until the access panel clears the
front lip, at the same time apply pressure (toward you) at the rear of the pedestal (shown as I~)
until the access panel moves toward you. Remove panel.
4.6.2 ETE-6-1 Multiline Terminal; Depress the flexible notched tab (shown as C) on the access panel
and apply upward pressure. Remove panel.
4.5
4.6
NOTE: Do not discard removed access panel: sate
forpossible future use.
4.7
4.8
4.9
4.10
4.11
4.12
4.13
Locate the four pin connector and jack labeled HAND (as
seen
through the access view of the Multiline
Terminal housing). Unplug this connector and extend it out from the housing access opening.
Set the SW2 Dip switches, on the ADA-E unit, as shown in Table 1 of Figure 2. Place the jumper across
pin ST2 and the center pin. Set SW1 to the BREAK position.
Make the wiring connections as indicated in Figure 2. The connections between Tl & T5
and
bctwccn
T2 & T4 are made with the jumper wires provided in the ADA-E kit. If
necessary, USC a
section of the
clear plastic tubing provided in the ADA-E kit to insulate the connections.
Locate and insert the four pin connector ended harness from the ADA-E unit into the jack
labeled
HAND on the Multiline Terminal.
Locate and insert the eight pin connector ended harness from the ADA-E unit into the jack labeled
ADA on the Multiline Terminal.
Insert the four pin connector ended harness (removed in step 4.7) into the four pin jack, CN3, located on
the ADA-E unit.
Install the ADA-E unit with the component side down ensuring the wires are not pinched. Sccurc the
ADA-E unit to the terminal housing with the screw provided as shown in Figure 3.
NOTE:
Two access panels are provided with the ADA-E kit; a narrow panel to be used with ElE6-I
Multiline Terminals and a wide panel to be used with all other terminals.
Knsure
the
correct access p;tnc!l is
used.
4.14 Route the locally provided station wire (already connected to the ADA-E unit) through one of the two
notched grooves on the access panel. Install the access panel.
4.15 Install the RJ-35X block in a convenient location. Connect the station cable from the ADA-E unit to
the RJ-35X block, connecting Red to Red, Green to Green, etc.
4.16 Plug the modular cord from the Autodialer into the
M-35X
receptacle.
4.17 Slide the directory back into place, if required.
2of6