user manual

ET1 NUMBER: MK-006
DATE:
FEBRUARY,
1988
4.9 Connect the modular handset cord and test the station for RF1 and normal audio levels. If
RF1 is still present,
open the handset, remove the capacitor between the transmitter and receiver
elements, and join both handset halves. Continue to step
4.10.
CAPACITOR
STEP 4.3
.
.Ol
pF CERAMIC
DISK CAPACITOR
STEP 4.7
Ill v
STEP 4.3
.Ol
pF CERAMIC
i LEADS
DISK CAPACITOR
Figure 1 Handset with all Three Capacitors Installed