user manual

ETI NUMBER: MK-01 2A
6.4 Electra Markll System programming (Refer to the Electra Markll Installation Service Manual)
.x
6.4.1
6.4.2
6.4.3
6.4.4
6.4.5
6.4.6
Assign individual trunks for DIT or ANA operation in Memory Blocks 283 and 284. (Delay
Announcement is available for DIT or ANA trunks only).
Assign the Delay Announcement feature to each required DIT or ANA trunk in Memory Block 2C5.
Assign desired time delay between incoming ring signal recognition and the start of the Delay
Announcement to the calling party in Memory Block 202, using line key 6. This timer is adjustable
from 1 to 99 seconds. System default value is 20 seconds.
Assign the desired Delay Announcement Auto Release Timer in Memory Block 2D1, using line key
3. This timer determines how long an outside line will remain connected to the announcement
device after encountering either a busy signal or no answer from a Hunt Group. If the outside line
can provide a remote disconnect signal this timer is not required, the remote disconnect will
supersede this timer. Timer ranges from 10 to 980 seconds with 990 being infinity, and can be
disabled. Default value is 600 seconds (10 minutes).
Select one of the ECR-E ETU relays to activate the announcement unit in Memory Block 2C9. Use
of relay number 10 is recommended for the first announcement. Relay number 9 is recommended
for the second delay announcement. (See Figure 1).
Assign the duration for the first and second delay announcements in memory block 2D2. Line
Key 7 represents the first announcement and Line Key 8 represents the second announcement.
Timer ranges are from l-98 seconds with 99 being infinity. Default is 10 seconds (Series 400 only).
NOTE: If the timer assignment is between l-98 seconds, MOH will automatically begin after the assigned. time.
If
timer assignment is 99, the announcement will continue to replay (same as Series 300).
6.4.7 Assign the MOH duration between the first and second announcements (LK2) and between the
second and repeat of the second announcement (LK8) in memory block 2Dl. timer ranges are
from 1 O-980 seconds with 99 being infinity (Series 400 only).
NOTE:
If the time assignment between the 1st and 2nd announcement is lo-980 seconds, JK3 (2nd Announcement
input) will automatically be the input for the Second Delay Announcement and the TSW-E/EB MOH inputs
become the input for Station BGM. If the timer is left at default, 99 (infinity), JK3 is the input for Station
BGM.
6.4.8
If station Hunt Groups are required, use Memory Blocks 385 through 388 to assign the required
parameters.
7. ATTENDANT ACTIVATION AND DEACTIVATION OF DELAY ANNOUNCEMENT
7.1 To Activate Day/Night Time Delay Announcement: (Idle mode)
7.1.1
Depress the CNF key.
7.1.2
For Day Time Delay Announcement, depress line key 9 (LED turns ON)
7.1.3
For Night Time Delay Announcement, depress line key 10 (LED turns ON)
7.1.4 Depress the CNF key to return ON LINE.
7.2 For deactivating Day time and Night time Delay Announcement, repeat the same procedure for activating
the announcement, except turn the LEDs OFF instead of ON.
4OF7