Punch down 24AWG one pair wire into Tip(T)
and
Ring (R) of SLI-EB port at the MDF.
Punch down the other end of this wire to one of the available channels (T IN and R IN) of the 155 Mk2
quick-connect block.
Punch down the 24 AWG one pair wire to the PT and PR of the SLI-EB port being used.
Half tap the other end of this wire to the Ground Start Trunk that is being used at the MDF.
Using the 24 AWG wire, connect GND on the quick-connect block to frame ground of the Electra Mark II.
Frame ground is located on the outside of the ESE-326-l CCU.
Using a modular jack, connect T OUT and R OUT by using the 24AWG one pair wire.
Plug the modular line cord (with RJl 1 connectors) into the modular jack and the SLT.
5. TEST PROCEDURES
5.1 With the Electra Mark II system operating, make outgoing and incoming calls with/to the SLT.
NOTE
For the following procedure, be sure that the CPU battery is ON.
5.2 Power down the Electra Mark II system and make outgoing and incoming calls with/to the SLT.
T
co
7
R
GROUND STARTTRUNK
Ch 1
SLI-EB
PT
SLT
IN OUT
9
FG
GND
NOTE: This unit can handle
a maximum of 3 SLTs
I
“_ .,
Figure 1. Connecting DEES Automatic Ground Start to an SLT.