Electra Markll Programming
7.4.1
A CO line appearance representing the CO port for the Viking products must be assigned to the
appropriate stations that will be answering and controlling them. MB 1A can be used for this
assignment.
7.4.2
Test the Viking W-1000/W-2000 for proper operation in conjunction with the Electra Markll
For configuration 2.3 (Door Release connected to VMI port). See Figure 3.
7.5.1 Determine the location for mounting the Viking RC-2A Remote Touch-Tone
On/Off Industrial
Controller Door Release. Ensure that there is an indoor 12OV ac.power source nearby.
7.5.2
7.5.3
Install the VMI-E ETU in an available interface slot (if a VMI port is not already available).
Install the RSG-E Unit in an available RSG slot, in the same or adjacent Electra Markll CCU where
the VMI-E ETU is installed, provided an RSG-E Unit is not already installed.
7.5.4
Insert the RJll connector end of the modular line cord into the RJ-OUT of the Viking RC-2A Door
Release.
7.5.5
7.5.6
Insert the other RJl 1 connector into the modular jack representing the available
VMI
port.
Set the Entry (Security) Code (a security code is required before the relays can be
activated/deactivated) of the Viking RC-2A by rotating the dials shown under Entry Code l-2-3.
7.5.7
Plug the unit into the nearest 120V ac outlet.
i -/
i Electra Markll programming
7.6.1
To control the Viking RC-2A Door Release, a
* must be sent first; therefore, MB 2A5, Line Key 1
must be turned off.
7.6.2
DTMF digit duration must be increased for sending control codes to the Viking RC-2A Door
Release. The VMI port that the Viking products are connected to, MB 4B9, Line Keyes 5-8 must be
changed to OFF-OFF-ON-OFF.
7.6.3
Connect additional equipment that is to be controlled by the Viking RC-2A to contacts A and B.
The “shunt” on the RC-2A (representing Normally Closed or Normally Open) may need to be
changed (depends on requirements of additional equipment).
7.6.4
Test the Viking RC-2A for proper operation in conjunction with the Electra Markll. Testing can be
accomplished using the following procedures.
A. Dial station number representing the VMI port.
B. After RC-2A answers, enter * and Entry Code.
C. Enter Command Codes and listen for confirmation tone.
5OF6