user manual

ETI NUMBER: DS-007
6.4 Remove the access panel by applying pressure (at the notch of the panel) and slide the access panel out as -.
shown in Figure 1.
;I
Apply Pressure and
ut the Access Panel
Dterm II Telephone
Figure 1. Access Panel Removal
6.5 Unscrew the two captive screws from the bottom of the housing. Separate the upper and bottom
housings
as shown in Figure 2.
6.6 Obtain an RJ-35X modular jack, four 24 AWG conductor wires and four small spade lugs.
6.7 Remove l/4” (approximately) of wire insulation from both ends of all four pieces of 24AWG wires. Solder
or crimp a spade lug to one end of each wire.
6.8 Make the RJ-35X connections (refer to Figure 3) using the prepared 24 AWG wires (wire end without spade
lug). Route the other end (with spade lug) of the 24 AWG wires through the access panel window to make
connections on the PCB of the Dterm II (refer to Table - 1 and Figure 3).
6.9 After the connections are made, replace the upper and lower housings by following the steps below
A. Ensure the handset modular socket is properly placed in the correct position.
B.
Position the lower housing on top of the upper housing. All wires should be routed out from the
access panel window.
C.
Slide the lower housing upwards so that the self-locking tabs on the bottom of the telephone are
aligned.
D. Pull the lower housing upward while pressing it onto the upper housing until the self-locking tabs
engage.
E. Secure the housings with the two captive screws that were removed in step 6.5.
2OF5