user manual

DATE: DECEMBER 1988
4. OPERATION
4.1
Access an idle CO/PBX line.
4.2
On the Autodialer, depress the ON/OFF button; then depress the desired Speed Dial button.
4.3
Monitor the call through the speaker of the Autodialer.
4.4
When called party answers, lift the handset and converse.
4.5
After call is established, manually turn OFF the Autodialer by depressing it’s ON/OFF button.
5. PROCEDURE
5.1
Turn the Multiline Terminal upside down (face down) and locate the access panel on the bottom of the
Multiline Terminal, refer to Figure 1.
5.2 Disconnect the modular line cord from under the telephone and from the ELJ-llC!/W jack.
5.3 Disconnect the modular handset cord from the lower housing.
5.4
Slide the directory out of the way (Not required for ETE-6-2 or ETE-16-2 Multiline Terminal).
5.5
Removal of access panel (Perform only the step that applies, either 5.5.1 or 55.2) Refer to Figure 1.
5.5.1
ETE-6D-2 or ETE-16D-2 Multiline Terminal; Insert flat screwdriver blade into notched opening shown as
A) and apply light upward pressure until access panel is cleared of the front lip, at the same time apply
pressure (towards you) at the rear of the pedestal (shown as B) until the access panel moves towards you.
Remove panel.
5.5.2 ETE-6-2 or ETE-16-2 Multiline Terminal, depress spring loaded notched tab (shown as C) on the access
panel and apply upward pressure. Remove panel.
5.6
5.7
5.8
5.9
5.10
5.11
ET1 NUMBER: DT-002
NOTE: Do not discard removed access panel. While it will not be used at this time, save for possible future
Locate the eight pin jack labeled “ADA”, as seen through the housing access opening of the Multiline
Terminal housing.
Unplug the four pin connector ended harness (labeled “HAND”) and extend it out from the housing access
opening, of the Multiline Terminal.
Set the Dip switches on the ADA-E unit as shown on Table 1 (See Figure 3). Place the jumper strap across
ST2 and the center pin. Set SW1 to the “BREAK” position.
Remove approximately 3 inches of outer insulation from both ends of the 4 conductor station wire cable and
strip off + inch of wire insulation from each of the four wires; solder or crimp a spade lug to each wire end.
Make the RJ-35X connections as indicated in Figure 3 using the prepared 4 conductor station wire cable.
Use one of the two spade tipped jumper wires provided with the ADA kit to make a connection between Tl
and T5; connect the other jumper wire between T2 and T4 on the ADA-E unit.
Locate and insert the four pin connector ended harness from CNl on the ADA-E unit into the jack labeled
“HAND” in the Multiline Terminal.
2of6