4.5 From one end of the two conductor wire (Step 3.3) remove approximately 4 inches of outer insulation and .“,
strip off + inch of the inner insulation from each of the two wires. To each conductor fasten one of the
spade lugs locally provided, either by soldering or crimping.
4.6 To remove the access panel, perform only the step that applies, either 4.6.1 or 4.6.2 (Refer to Figure 1).
4.6.1
ETE-6D-0, ETE-16D-0 or, ETE-16K-1 Multiline Terminal; Insert a flat screwdriver blade into notched
opening (shown as A) and apply light upward pressure until the access panel clears the front lip, at
the same time, apply pressure (toward you) at the rear of the pedestal (shown as B) until the access
panel moves toward you . Remove panel.
4.6.2 ETE-6-O or ETE-16-O Multiline Terminal; Depress the flexible notched tab (shown as C) on the
access panel and apply upward pressure. Remove panel.
NOTE:
Do not discard removed access panel; save for possible future use.
4.7 Locate the four pin connector and jack labeled HAND (as seen through the access view of the Multiline
Terminal housing). Unplug this connector and extend it out from the housing access opening.
4.8 Set the SW2 Dip switches, on the ADA-ER unit, as shown in Table 1 of Figure 2. Place the jumper across pin
ST1 and the center pin. Set SW1 to the BREAK position.
4.9 Make the wiring connections as indicated in Figure 2. If necessary, use a section of the clear plastic
tubing provided in the ADA-ER kit to insulate the connections.
4.10 Locate and insert the four pin connector ended harness from the ADA-ER unit into the jack labeled.HAND
on the Multiline Terminal.
4.11 Locate and insert the eight pin connector ended harness from the ADA-ER unit into the jack labeled ADA
on the Multiline Terminal.
4.12 Insert the four pin connector ended harness (removed in step 4.7) into the four pin jack, CN3, located on
the ADA-ER unit.
4.13 Install the ADA-ER unit with the component side down ensuring the wires are not pinched. Secure the
ADA-ER unit to the terminal housing with the screw provided as shown in Figure 3a [ETE-6D-0, ETE-16D-()
or, ETE-16K-I] or, 3b [ETE-6-O or, ETE-16-O]
NOTE
Two access panels are provided with the ADA-ER kit; a narrow
panel to be used with ETE-6-O or ETE-16-O Multiline Terminals,
and a wide panel to be used with all other terminals. Ensure the
correct access panel is used.
4.14 Route the locally provided cable (already connected to the ADA-ER unit) through the cable exit grooves
on the access panel. Install the access panel. (Refer to Figure 3 for cable exit groove location)
4.15 Slide the directory back into place, if required.
4.16 Reinstall the handset and modular line cords onto the Multiline Terminal.
--