user manual

ETI NUMBER: MK-015
7.2 Electra Markll Programming
7.2.1 A CO line appearance representing the CO port for the Viking products must be assigned to the
appropriate stations that will be answeiing and controlling them. MB 1A can be
used
for this
assignment.
7.2.2 To control the Viking RC-2A Door Release, a
l
must be sent first; therefore, MB 2A5, Line Key 1
must be turned off.
7.2.3 DTMF digit duration must be increased for sending control codes to the Viking RC-2A Door
Release. The CO port that the Viking products are connected to, MB 48 1, Line Keyes 5-8 must be
changed to OFF-OX-ON-OFF.
7.2.4
Test the Viking W-1000/W-2000, and RC-2A for proper operation in conjunction with the Electra
Markll.
7.3 For configuration 2.2 (Handsfree Doorbox connected to COI-E/EB ETU). See Figure 2.
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
Determine the location for mounting the Viking W-1000/W-2000 Handsfree Doorbox and/or
Viking RC-2A Remote Touch-Tone On/Off Industrial Controller Door Release. Ensure that there is
an indoor 12OV ac power source nearby.
Install the COI-E/EB ETU in an available interface slot
(if
a COI port is not already available). The
COI-E/E6 ETU port to be used must be set as a Loop Start Trunk.
Using the 24 AWG one pair wire, punch down the wire onto the Tip and Ring of the available COI
port at the MDF.
Connect the other end of the 24 AWG one pair wire to the Viking W-1000/W-2000 as shown in
Figure 2.
Connect the power supply to the W-lOOOMI2000 and plug into the nearest 12OV ac outlet.
f
/
0
TOP
\
0
To Tip & Ring
ofa
COI-E/EB ETU Port
I
0
II
0
13SVac
Power
12OV ac
W-l 000 or W-2000
(Rear View)
Figure. 2 Handsfree Doorbox connected to COI-E/EB ETU
4OF6