user manual

ETI NUMBER: DS-004
6.8
TA-20: For ETE-1-2
Revision B and higher.
Connect the leads from the TA-20 Handset Amplifier to the
spade lug connectors on the ETE-1-2 PCB. Refer to Table- 3 and Figure 4. Needlenose pliers may be used to
push spade lugs into the receptacles.
6.9 S-l 1: For ETE-l-2 Revision B and higher.
Connect the leads from the S-l
1
Handset Amplifier to the spade
lug connectors on the ETE-l-2 PCB. Refer to Table - 4 and Figure 5. Needlenose pliers may be used to push
spade lugs into the receptacles.
6.10 Following the pre-molded guides inside the access panel cover assembly, cut the notch and route.the TA-20
or S-l 1 cable through this notch. (See Figure 6.)
6.11 Attach the access panel cover to the Dterm II main body.
6.12 Use a piece of double sided tape to secure the TA-20 or S-l 1 Handset Amplifier to the side of the Dterm II
telephone.
6.13 Connect the line and handset cords to the Dterm II.
6.14 Test for normal operation
NOTE: If the TA-20 or S-l 1 is disconnected from the ETE-l-2 telephone, Strap 58 must be reconnected for proper
operation of the telephone.
Table
-
3 TA-20 Handset Amplifier Cable Connection (ETE-1-2 Rev. B or higher)
TA-20 HANDSET AMPLIFIER CABLES
DTERM SPADE LUG CONNECTORS
YELLOW RX1
RED RX2
GREEN
Jl
BLACK
J3
*
Remove the existing spade lug connector from RX1 and plug it in Jl.
**
Cut Strap 58 on the PCB.
Table
-
4 S-l 1 Handset Amplifier Cable Connection (ETE-l-2 Rev. B or higher)
I
S-11
HANDSET
AMPLIFIER
CABLES
I
DTERM SPADE LUG CONNECTORS
I
YELLOW
RX1
RED
RX2
I ~~
GREEN
I
RX3
I
BLACK
I
J3
*
Remove the existing spade
lug connector from
RX1
and plug it in
Jl.
** Cut Strap 58 on the PCB.
4OF6