ND-20292
CHAPTER 7
APRIL. 1990
2.
3.
Insufficient Data
When this program is transferred from the
LCR-E ETU to the computer and an LCR
program was created (which does not produce
enough information to allow Call Routing), a
display, similar to the one to the right, is
shown.
Electra Mark II Not Ready
If
the computer is unable to communicate with
the LCR-E ETU, a display similar to the one at
the right is shown.
NOTE:
During the input of data or commands, if
an invalid input is keyed into the
computer, it will generate a beep tone to
indicate an invalid command or data was
entered.
SAMPLE LCD INDICATIONS
ROUTE ADVANCE TABLE DOWN LOAD START
ABNORMAL END
SYS DATA INCOMPLETE
4
AREA CODE TABLE DOWN LOAD START
‘ABNORMAL END
KEY SYS NOT READY
4
ERROR
REASON
POSSIBLE SOLUTION COMMAND MODE
Line Trouble
LCR-E ETU and computer
Check RS-232C cable. Verify cable
Down Load
Disk Drive not
connections. Ensure LCR-E ETU
Up Load
communicating properly
Busyout switch is ON Verify
System Control
FDD I/O
Error
Computer and Disk Drive not
Check cable between computer and
All commands except
communicating properly
Disk Drive. Check power on Disk System Control
Drive. Check for properly inserted
diskette. Check that diskette write
protect tab is set properly.
Printer Not Computer cannot
Check connections to printer. Check
Print Out
Ready
communicate with printer
printer power. Check that printer is
ON LINE. Check paper feed.
LCR
Restarted
LCR-E restart during
command associated with
LCR-E
Check baud rate on COM Port and
LCR-E card. Replace LCR-E.
Down Load
Up Load
Verify
System Control
System Data
Insufficient Data received
Check LCR program. Down Load all
Down Load
Incomplete
from LCR-E
Tables. Replace LCR-E
Key System
Invalid data or no data from
Check LCR-E switch settings. If Down Load
Not Ready LCR-E
settings are correct, replace LCR-E.
Beep Tone
Invalid input keyed in.
Check cursor position to determine All command modes
required input and enter valid entry.
700 - 58