user manual

ND-20292
CHAPTER 9
APRIL, 1990
C.
D.
E.
Proceed to retype the information, line by line, that
After communication with the remote site is
was included in your previous CONFIGSYS File.
After this information has been typed in, type
established, exit from the COMLINK program to the
A: > prompt. This can be done as follows:
-. 1,
I
DEVICE =ANSI.SYS and press RETURN.
i
1. Press (ES0 key.
Press (CTRL) Z and RETURN.
2. The screen prompts you if you are calling another
system or if you wish to use DATASAVE. Press
Reboot the system. (This can be done by pressing
(ES0 key.
(CTRL) (ALT) (DEL) at the same time.)
3. The screen then prompts you that you are exiting
the RAA emulator. Press any key to exit.
950.4
CREATING A DIRECTORY
A Directory must first be created on either the
computer hard disk, or a Double Sided High Density
diskette. A name or code (maximum of eight
alpha/numeric characters) for a particular customer
site is recommended; (Example: ABC). The following
procedure is required to create a Directory:
From the Disk/Hard Drive prompt representing the
location where the data is to be stored, type the
command “MD\” followed by the Directory file name
that is being created. (Example A: > MD\ABC) This
will create a Directory file for the location of the
system data under “ABC”.
To remove this directory, delete all files in the
2. To start the program. Enter “Datasave” and press
directory first, then from the A: > prompt, for example,
c(Return1 at the A:> prompt if you are using the
type the command “RD\” followed by the directory
COMl Port. When the COM2 Port is being used,
name.
the following must be entered: “DATASAVE 2”
4. You
are now at the A > or B > prompt.
5. Proceed with Step 1 of Section 950.6 (Operating
Procedures).
NOTE:
After any programming is done to the
remote Electra Mark11 System with the
COMLINK software, you can escape from
this program to use the System Data
Up/Down Load program by using the same
modem connection.
950.6 OPERATING PROCEDURES
1.
Install the “DATASAVE” diskette into the PC disk
drive.
950.5 REMOTE OPERATION SETUP
From a remote location, you must use the IBM V2.0 of
COMLINK software with the RAA to establish
communication with the remote site. To establish this
communication, refer to the Electra Mark11
Installation Service Manual, Chapter 9, Section 940.5
(Parts A and B).
and press t(Return). Display shows:
c ELECTRA MARK 2 DIGITAL KEY TELEPHONE SYSTEM >
SYSTEM MEMORY UP LOAD /DOWN LOAD
(C) COPYRIGHT
NEC CORPORATION 1990
ENTER DISK DRIVE (AND PATH):
VERSION X.Xx
L
900 - 16